Air-cooled Chiller KIC-25A
Air-cooled Chiller KIC-25A
Air-cooled Chiller KIC-25A
+
  • Air-cooled Chiller KIC-25A
  • Air-cooled Chiller KIC-25A
  • Air-cooled Chiller KIC-25A
undefined
undefined
undefined
+
  • undefined
  • undefined
  • undefined

Number:

KIC-25A

Air-cooled Chiller KIC-25A

The “Kornai” series of industrial chillers can deliver chilled water at temperatures ranging from 3°C to 30°C, with special low-temperature models capable of reaching as low as -25°C (with a temperature differential not exceeding ±1°C). Air-cooled chillers offer cooling capacities from 7,482 to 154,800 kcal/h (equivalent to compressor powers from 3 to 60 HP) and are widely applicable across various industries. For instance, in the plastics industry—such as injection molding and vacuum forming—chillers can precisely control the temperature of plastic molding molds, thereby shortening cycle times, accelerating product stabilization, preventing deformation and shrinkage, enhancing surface finish, and improving transparency. They are also suitable for cooling the spindle lubricating oil and hydraulic transmission fluid in CNC machine tools, coordinate boring machines, grinders, machining centers, modular machine tools, and other precision machine tools, enabling precise oil temperature control, effectively reducing thermal deformation, and improving machining accuracy. In addition, these chillers are ideal for use in electroplating, food processing, dyeing and bleaching, and other industries as well.

隐藏域元素占位

Keywords

  • Product Description
  • Specifications
    • Commodity name: Air-cooled Chiller KIC-25A
    • Commodity ID: KIC-25A

    The “Kornai” series of industrial chillers can deliver chilled water at temperatures ranging from 3°C to 30°C, with special low-temperature models capable of reaching as low as -25°C (with a temperature differential not exceeding ±1°C). Air-cooled chillers offer cooling capacities from 7,482 to 154,800 kcal/h (equivalent to compressor powers from 3 to 60 HP) and are widely applicable across various industries. For instance, in the plastics industry—such as injection molding and vacuum forming—chillers can precisely control the temperature of plastic molding molds, thereby shortening cycle times, accelerating product stabilization, preventing deformation and shrinkage, enhancing surface finish, and improving transparency. They are also suitable for cooling the spindle lubricating oil and hydraulic transmission fluid in CNC machine tools, coordinate boring machines, grinders, machining centers, modular machine tools, and other precision machine tools, enabling precise oil temperature control, effectively reducing thermal deformation, and improving machining accuracy. In addition, these chillers are ideal for use in electroplating, food processing, dyeing and bleaching, and other industries as well.

    The “Kolnai” series of industrial chillers can deliver chilled water at temperatures ranging from 3°C to 30°C, with special low-temperature models capable of reaching as low as -25°C (with a temperature differential not exceeding ±1°C). Air-cooled chillers,
    Cooling capacities range from 7,482 to 154,800 kcal/h (compressor powers from 3 to 60 HP), making them suitable for a wide range of industries. For example, in the plastics industry, they are used for injection molding, vacuum forming, and chilled water applications.
    The machine can precisely control the temperature of the plastic molding mold to shorten the molding cycle, accelerate product setting, prevent deformation and shrinkage, and improve surface finish.
    Cleanliness and enhanced transparency; also suitable as spindle lubricating oil for CNC machine tools, coordinate boring machines, grinders, machining centers, modular machine tools, and various precision machine tools, and
    Cooling of the hydraulic transmission medium enables precise control of oil temperature, effectively reducing thermal deformation of machine tools and improving machining accuracy; it is also suitable for the electroplating and food industries,
    The dyeing and bleaching industry and other industries.

     

    Model Unit
    Unit
    KIC-3A KIC-5A KIC-6A KIC-8A KIC-10A KIC-12A KIC-15A KIC-20A KIC-25A KIC-30A KIC-40A KIC-50A KIC-60A
    Cooling capacity
    Refrigerating capacity
    kcal/h 7482 11782 14620 19264 23564 28724 36550 49536 57448 70692 94256 114896 154800
    Keyword 8.7 13.7 17 22.4 27.4 33.4 42.5 57.6 66.8 82.2 109.6 133.6 180
    Total Input Power kW
    Total power input
    Keyword 3.43 5.15 6.05 8.19 9.59/9.94 11.45/11.8 15.1 19.7/20.4 23.6 31.2 40.4 48.3 64.3
    Refrigerant
    Refrigerant
    - R22
    Operation Control Mode
    Running control method
    - Digital Microcomputer Temperature Controller
    Power supply
    Power supply
    - 3N, 380V, 50Hz
    Safety Protection Device
    Safety protection devices
    - Overload protection, reverse phase protection, high/low voltage protection, low water flow protection, low liquid level protection, freeze protection, and more.
    Compressor
    Compressor
    Form Type Fully enclosed rotary or scroll type
    Compressor power in kW 2.7 4 4.9 6.6 8 9.6 12 16 19.2 24 32 38.4 54.4
    Condenser
    Condenser
    Type High-efficiency red copper bushing with aluminum finned heat exchanger + low-noise external-rotor fan
    Air flow rate m³/h 3000 5000 6000 8000 10000 12000 15000 20000 25000 30000 40000 50000 60000
    Fan power kW 0.18 × 2 0.2 × 2 0.2 × 2 0.42 × 2 0.42 × 2 0.55 × 2 0.8 × 2 1.1×2 1.1×2 0.8 × 4 1.1×4 1.1×4 1.1×4
    Evaporator
    Evaporator
    Type Water-tank coil type/dry shell-and-tube type
    Inlet and outlet pipe diameter (inches) 1 1 1 1.5 1.5 2 2 2.5 2.5 2.5 3 3 3
    Water tank capacity L
    Water tank capacity
    L 50 50 70 120 120 120 120 200 200 200 400 400 400
    Pump
    Pump
    Flow rate L/min 40 50 50 80 80/100 80/100 150 150/200 200 300 300 500 500
    Pressure bar 1.7 1.7 1.7 1.7 1.7 1.7 1.9 2.1 2.1 2.1 2.1 2.1 2.1
    Power kW 0.37 0.75 0.75 0.75 0.75/1.1 0.75/1.1 1.5 1.5/2.2 2.2 4 4 5.5 5.5
    External dimensions
    External dimensions
    Length A mm 1122 1122 1322 1530 1530 1530 2000 2000 2000 2300 2300 2300 2800
    Width B mm 620 620 734 800 800 800 1000 1000 1000 1800 1800 1800 1800
    High C mm 1180 1180 1300 1480 1480 1480 1960 1960 1960 1800 1800 1800 1800
    Refrigerant Charging Quantity (kg)
    Refrigerant filling
    kilogram 2.7 4.3 5 7 8.6 10 13 17 21 25 33 42 50
    Remarks 1. The cooling capacity is based on a chilled water inlet temperature of 15°C, a chilled water outlet temperature of 10°C, and an ambient temperature of 35°C.
    2. The Company reserves the right to modify the above parameters without prior notice. Custom specifications may be designed and modified upon request.

Product Details

The “Kolnai” series of industrial chillers can deliver chilled water at temperatures ranging from 3°C to 30°C, with special low-temperature models capable of reaching as low as -25°C (with a temperature differential not exceeding ±1°C). Air-cooled chillers,
Cooling capacities range from 7,482 to 154,800 kcal/h (compressor powers from 3 to 60 HP), making them suitable for a wide range of industries. For example, in the plastics industry, they are used for injection molding, vacuum forming, and chilled water applications.
The machine can precisely control the temperature of the plastic molding mold to shorten the molding cycle, accelerate product setting, prevent deformation and shrinkage, and improve surface finish.
Cleanliness and enhanced transparency; also suitable as spindle lubricating oil for CNC machine tools, coordinate boring machines, grinders, machining centers, modular machine tools, and various precision machine tools, and
Cooling of the hydraulic transmission medium enables precise control of oil temperature, effectively reducing thermal deformation of machine tools and improving machining accuracy; it is also suitable for the electroplating and food industries,
The dyeing and bleaching industry and other industries.

 

Model Unit
Unit
KIC-3A KIC-5A KIC-6A KIC-8A KIC-10A KIC-12A KIC-15A KIC-20A KIC-25A KIC-30A KIC-40A KIC-50A KIC-60A
Cooling capacity
Refrigerating capacity
kcal/h 7482 11782 14620 19264 23564 28724 36550 49536 57448 70692 94256 114896 154800
Keyword 8.7 13.7 17 22.4 27.4 33.4 42.5 57.6 66.8 82.2 109.6 133.6 180
Total Input Power kW
Total power input
Keyword 3.43 5.15 6.05 8.19 9.59/9.94 11.45/11.8 15.1 19.7/20.4 23.6 31.2 40.4 48.3 64.3
Refrigerant
Refrigerant
- R22
Operation Control Mode
Running control method
- Digital Microcomputer Temperature Controller
Power supply
Power supply
- 3N, 380V, 50Hz
Safety Protection Device
Safety protection devices
- Overload protection, reverse phase protection, high/low voltage protection, low water flow protection, low liquid level protection, freeze protection, and more.
Compressor
Compressor
Form Type Fully enclosed rotary or scroll type
Compressor power in kW 2.7 4 4.9 6.6 8 9.6 12 16 19.2 24 32 38.4 54.4
Condenser
Condenser
Type High-efficiency red copper bushing with aluminum finned heat exchanger + low-noise external-rotor fan
Air flow rate m³/h 3000 5000 6000 8000 10000 12000 15000 20000 25000 30000 40000 50000 60000
Fan power kW 0.18 × 2 0.2 × 2 0.2 × 2 0.42 × 2 0.42 × 2 0.55 × 2 0.8 × 2 1.1×2 1.1×2 0.8 × 4 1.1×4 1.1×4 1.1×4
Evaporator
Evaporator
Type Water-tank coil type/dry shell-and-tube type
Inlet and outlet pipe diameter (inches) 1 1 1 1.5 1.5 2 2 2.5 2.5 2.5 3 3 3
Water tank capacity L
Water tank capacity
L 50 50 70 120 120 120 120 200 200 200 400 400 400
Pump
Pump
Flow rate L/min 40 50 50 80 80/100 80/100 150 150/200 200 300 300 500 500
Pressure bar 1.7 1.7 1.7 1.7 1.7 1.7 1.9 2.1 2.1 2.1 2.1 2.1 2.1
Power kW 0.37 0.75 0.75 0.75 0.75/1.1 0.75/1.1 1.5 1.5/2.2 2.2 4 4 5.5 5.5
External dimensions
External dimensions
Length A mm 1122 1122 1322 1530 1530 1530 2000 2000 2000 2300 2300 2300 2800
Width B mm 620 620 734 800 800 800 1000 1000 1000 1800 1800 1800 1800
High C mm 1180 1180 1300 1480 1480 1480 1960 1960 1960 1800 1800 1800 1800
Refrigerant Charging Quantity (kg)
Refrigerant filling
kilogram 2.7 4.3 5 7 8.6 10 13 17 21 25 33 42 50
Remarks 1. The cooling capacity is based on a chilled water inlet temperature of 15°C, a chilled water outlet temperature of 10°C, and an ambient temperature of 35°C.
2. The Company reserves the right to modify the above parameters without prior notice. Custom specifications may be designed and modified upon request.
  • Strong safety performance: Provide multiple anti-theft designs to ensure the safety of home and property.
  • High durability: Made of high-quality materials, corrosion-resistant and wear-resistant, with a long service life.
  • Appearance diversity: Rich design styles, perfect match with various decorations.
  • Easy operation: Intelligent design, no key required, simple and efficient to use.
  • Multifunctionality: With alarm prompts and networking functions, it meets the needs of multiple scenarios.
  • Easy installation: Compatible with a variety of door types, quick installation, and strong adaptability.

Certificate


Certificate
Certificate
Certificate

FAQ


Q

What are the common reasons for the mold temperature controller alarming and shutting down?


A

Common reasons include high-temperature protection, low liquid level alarm, overload protection, heating element failure, or pump malfunction.

Q

Why is the cooling performance of the chiller poor?


A

Possible causes include insufficient refrigerant, blocked condenser, compressor failure, or pipeline leakage. Inspections and repairs are needed.

Q

What is the working principle of a mold temperature controller (MTC)?


A

The MTC heats or cools the medium (such as water or thermal oil) to a set temperature and then circulates it through the mold or equipment via a pump to achieve precise temperature control.

Q

Why is the mold temperature controller heating up slowly?


A

Possible reasons include insufficient heating power, pump failure, pipeline blockage, or insufficient medium. These should be checked and resolved step by step.

Q

What is the difference between a mold temperature controller and a chiller?


A

The MTC is used for heating and maintaining the temperature of equipment or molds, while the chiller is mainly used for quickly cooling equipment or molds to lower the temperature.

< 12 >

Get A Quote

Note: Please leave your contact information and our professionals will contact you as soon as possible!

Submit

FOCUS ON TEMPERATURE CONTROL TECHNOLOGY

Contact

Fax: 86-750-3609612

Add: No. 38, Yecheng Industrial Zone, Kautou Star Village, Jianghai District, Jiangmen, Guangdong, China

Sign up for exclusive offers and updates!

Connnect with us!