- Commodity name: Water-cooled screw chiller unit
◆The heart of the most efficient semi-hermetic compressor unit—the imported high-quality screw compressor, featuring a 5:6 ultra-efficient helical rotor that delivers 20–30% higher energy efficiency than conventional compressors. It offers reliable operation, high efficiency, easy maintenance, precise energy control, and a wide range of applications. Key features include: 1) the latest asymmetric rotor tooth profile twin-screw design; 2) four-stage or stepless control systems; 3) a built-in differential-pressure oil supply and lubrication system; and 4) low vibration and low noise levels. ◆Microcomputer-based precise temperature control: the unit’s microcomputer controller is equipped with an extra-large touchscreen LCD display, providing a user-friendly, fully Chinese-language human–machine interface for automated front-end control. The LCD screen instantly displays the machine’s operating status, enabling precise monitoring to ensure the unit always runs at optimal performance. The touch panel is tightly sealed, offering excellent water-, dust-, and corrosion-resistance, with long-lasting key life. ◆Stepwise and infinitely variable energy control: for typical refrigeration and air-conditioning systems, the unit can be equipped with a 100%, 75%, 50%, or 25% stepwise energy control system, which maximizes energy savings under partial-load conditions. For applications requiring precise water-temperature control, infinitely variable energy control can be installed on all models upon customer request. High operational efficiency is further ensured by the use of high-efficiency internally threaded tubes from Kobe, Japan, in combination with a highly efficient screw compressor, guaranteeing superior performance. To prevent any operational failures, the chiller is also equipped with the following protective and auxiliary components: compressor protection timer, overcurrent relay, compressor motor temperature sensor, freeze-protection thermostat, sight glass, oil heater, compressor reverse-rotation protection relay, exhaust-overtemperature protection, safety valve, and fusible plug.
◆The heart of the most efficient semi-hermetic compressor unit: a high-quality imported screw compressor. Its 5:6 ultra-efficient helical rotor design delivers 20–30% higher energy efficiency than conventional compressors, while offering reliable operation, high efficiency, easy maintenance, precise energy control, and a wide range of applications. Key features include: 1) the latest asymmetric rotor tooth profile twin-screw design; 2) a four-stage or stepless control system; 3) a built-in differential-pressure oil supply and lubrication system; and 4) low vibration and low noise.
◆The microcomputer provides precise temperature control; the unit’s microcomputer controller features an extra-large, touch-enabled LCD display with a fully Chinese-language human–machine interface, enabling automated control of all functions. The LCD screen displays the machine’s operating status in real time, allowing for accurate monitoring of the unit’s operation to ensure it remains in optimal condition. The control panel is tightly sealed, offering excellent water and dust resistance as well as corrosion protection, with long-lasting key life.
◆Stepless and infinitely variable capacity control, suitable for general refrigeration and air-conditioning systems, is available with 100%, 75%, 50%, and 25% step-capacity control options. This capacity control ensures maximum energy savings under partial-load conditions; however, for precise water-temperature control, infinitely variable capacity control can be configured on all models upon customer request. The unit boasts high operational efficiency, featuring a heat exchanger equipped with high-efficiency internally threaded tubes manufactured in Kobe, Japan, paired with a highly efficient screw-type compressor, thereby guaranteeing superior performance. It also incorporates the most reliable protective and auxiliary components to prevent any operational failures: a compressor protection timer, an overcurrent relay, a compressor motor temperature sensor, an anti-freeze thermostat, a sight glass, an oil heater, a compressor reverse-rotation protection relay, exhaust-overtemperature protection, a safety valve, and a fusible plug.Model
ParametersKIC-100WS KIC-140WS KIC-180WS KIC-200WS KIC-230WS KIC-260WS KIC-300WS KIC-340WS KIC-370WS KIC-410WS KIC-470WS Cooling capacity (2/40°C)
Cooling capacityX1000 kcal 86 120.4 154.8 172 197.8 223.6 258 292.4 318.2 352.6 404.2 KW/hr 100 140 180 200 230 260 300 340 370 410 470 Temperature range 5℃ - Room temperature (Below 0℃ can be customized) Power supply 3N- 380V/415 50HZ/60HZ Compressor Form Semi-hermetic screw Power: Power kW 22 30 36 41 51 56 61 70 80 88 102 Current A 39 51 65 71 86 95 106 122 135 150 172 Energy regulation 0-33%-66%-100% 0-25%-50%-75%-100% Condenser Form Shell and tube Water volume m³/h 22.4 29.2 35.2 42.9 53.6 57.8 67.1 74.3 84.3 89.4 107.5 Inlet and outlet pipe diameter G
Inlet and outlet pipe diameterG2.5" G3" G3" G3" G3" G3" G3" G4" G4" G4" G4" Evaporator Form Shell and tube Cold water volume Amount of cold water m³/h 17.2 22.4 29.3 33 40.8 43.9 51.6 56.8 64.2 68.8 81.6 Inlet and outlet pipe diameter G
Inlet and outlet pipe diameterG2.5" G3" G3" G3" G3" G3" G3" G4" G4" G4" G4" Machine size A/mm 2250 2300 2400 2500 2500 2550 2950 2950 2950 3000 3050 B/mm 800 800 800 900 900 900 900 900 900 900 1500 C/mm 1500 1600 1650 1750 1750 1800 1800 1850 1850 1950 1500 Unit weight kilogram 960 990 1260 1380 1450 1520 1710 1830 1940 2050 2400 Unit weight kilogram 1280 1300 1600 1830 1950 2070 2300 2400 2550 2650 3050 Note 1: The cooling capacity is based on a chilled water inlet temperature of 12°C, an outlet temperature of 7°C, and an ambient temperature of 35°C.
2. The Company reserves the right to modify the aforementioned parameters without prior notice. Custom specifications may be designed and modified upon request.
1. The above parameters are based on that chilled water inlet/outlet temperature is 12°C/7°C and environment temperature is 35°C.
2. The company reserves the right to modify the above parameters without prior notice. Special specifications may be customized separately.
Previous Page
Next Page
Product Details
◆The heart of the most efficient semi-hermetic compressor unit: a high-quality imported screw compressor. Its 5:6 ultra-efficient helical rotor design delivers 20–30% higher energy efficiency than conventional compressors, while offering reliable operation, high efficiency, easy maintenance, precise energy control, and a wide range of applications. Key features include: 1) the latest asymmetric rotor tooth profile twin-screw design; 2) a four-stage or stepless control system; 3) a built-in differential-pressure oil supply and lubrication system; and 4) low vibration and low noise.
◆The microcomputer provides precise temperature control; the unit’s microcomputer controller features an extra-large, touch-enabled LCD display with a fully Chinese-language human–machine interface, enabling automated control of all functions. The LCD screen displays the machine’s operating status in real time, allowing for accurate monitoring of the unit’s operation to ensure it remains in optimal condition. The control panel is tightly sealed, offering excellent water and dust resistance as well as corrosion protection, with long-lasting key life.
◆Stepless and infinitely variable capacity control, suitable for general refrigeration and air-conditioning systems, is available with 100%, 75%, 50%, and 25% step-capacity control options. This capacity control ensures maximum energy savings under partial-load conditions; however, for precise water-temperature control, infinitely variable capacity control can be configured on all models upon customer request. The unit boasts high operational efficiency, featuring a heat exchanger equipped with high-efficiency internally threaded tubes manufactured in Kobe, Japan, paired with a highly efficient screw-type compressor, thereby guaranteeing superior performance. It also incorporates the most reliable protective and auxiliary components to prevent any operational failures: a compressor protection timer, an overcurrent relay, a compressor motor temperature sensor, an anti-freeze thermostat, a sight glass, an oil heater, a compressor reverse-rotation protection relay, exhaust-overtemperature protection, a safety valve, and a fusible plug.
| Model Parameters |
KIC-100WS | KIC-140WS | KIC-180WS | KIC-200WS | KIC-230WS | KIC-260WS | KIC-300WS | KIC-340WS | KIC-370WS | KIC-410WS | KIC-470WS | |
| Cooling capacity (2/40°C) Cooling capacity |
X1000 kcal | 86 | 120.4 | 154.8 | 172 | 197.8 | 223.6 | 258 | 292.4 | 318.2 | 352.6 | 404.2 |
| KW/hr | 100 | 140 | 180 | 200 | 230 | 260 | 300 | 340 | 370 | 410 | 470 | |
| Temperature range | 5℃ - Room temperature (Below 0℃ can be customized) | |||||||||||
| Power supply | 3N- 380V/415 50HZ/60HZ | |||||||||||
| Compressor | Form | Semi-hermetic screw | ||||||||||
| Power: Power kW | 22 | 30 | 36 | 41 | 51 | 56 | 61 | 70 | 80 | 88 | 102 | |
| Current A | 39 | 51 | 65 | 71 | 86 | 95 | 106 | 122 | 135 | 150 | 172 | |
| Energy regulation | 0-33%-66%-100% | 0-25%-50%-75%-100% | ||||||||||
| Condenser | Form | Shell and tube | ||||||||||
| Water volume m³/h | 22.4 | 29.2 | 35.2 | 42.9 | 53.6 | 57.8 | 67.1 | 74.3 | 84.3 | 89.4 | 107.5 | |
| Inlet and outlet pipe diameter G Inlet and outlet pipe diameter |
G2.5" | G3" | G3" | G3" | G3" | G3" | G3" | G4" | G4" | G4" | G4" | |
| Evaporator | Form | Shell and tube | ||||||||||
| Cold water volume Amount of cold water m³/h | 17.2 | 22.4 | 29.3 | 33 | 40.8 | 43.9 | 51.6 | 56.8 | 64.2 | 68.8 | 81.6 | |
| Inlet and outlet pipe diameter G Inlet and outlet pipe diameter |
G2.5" | G3" | G3" | G3" | G3" | G3" | G3" | G4" | G4" | G4" | G4" | |
| Machine size | A/mm | 2250 | 2300 | 2400 | 2500 | 2500 | 2550 | 2950 | 2950 | 2950 | 3000 | 3050 |
| B/mm | 800 | 800 | 800 | 900 | 900 | 900 | 900 | 900 | 900 | 900 | 1500 | |
| C/mm | 1500 | 1600 | 1650 | 1750 | 1750 | 1800 | 1800 | 1850 | 1850 | 1950 | 1500 | |
| Unit weight | kilogram | 960 | 990 | 1260 | 1380 | 1450 | 1520 | 1710 | 1830 | 1940 | 2050 | 2400 |
| Unit weight | kilogram | 1280 | 1300 | 1600 | 1830 | 1950 | 2070 | 2300 | 2400 | 2550 | 2650 | 3050 |
| Note 1: The cooling capacity is based on a chilled water inlet temperature of 12°C, an outlet temperature of 7°C, and an ambient temperature of 35°C. 2. The Company reserves the right to modify the aforementioned parameters without prior notice. Custom specifications may be designed and modified upon request. 1. The above parameters are based on that chilled water inlet/outlet temperature is 12°C/7°C and environment temperature is 35°C. 2. The company reserves the right to modify the above parameters without prior notice. Special specifications may be customized separately. |
||||||||||||
- Strong safety performance: Provide multiple anti-theft designs to ensure the safety of home and property.
- High durability: Made of high-quality materials, corrosion-resistant and wear-resistant, with a long service life.
- Appearance diversity: Rich design styles, perfect match with various decorations.
- Easy operation: Intelligent design, no key required, simple and efficient to use.
- Multifunctionality: With alarm prompts and networking functions, it meets the needs of multiple scenarios.
- Easy installation: Compatible with a variety of door types, quick installation, and strong adaptability.
Certificate
FAQ
Q
What are the common reasons for the mold temperature controller alarming and shutting down?
A
Common reasons include high-temperature protection, low liquid level alarm, overload protection, heating element failure, or pump malfunction.
Q
Why is the cooling performance of the chiller poor?
A
Possible causes include insufficient refrigerant, blocked condenser, compressor failure, or pipeline leakage. Inspections and repairs are needed.
Q
What is the working principle of a mold temperature controller (MTC)?
A
The MTC heats or cools the medium (such as water or thermal oil) to a set temperature and then circulates it through the mold or equipment via a pump to achieve precise temperature control.
Q
Why is the mold temperature controller heating up slowly?
A
Possible reasons include insufficient heating power, pump failure, pipeline blockage, or insufficient medium. These should be checked and resolved step by step.
Q
What is the difference between a mold temperature controller and a chiller?
A
The MTC is used for heating and maintaining the temperature of equipment or molds, while the chiller is mainly used for quickly cooling equipment or molds to lower the temperature.