- Commodity name: Water-Cooled Chiller KIC-25W
- Commodity ID: KIC-25W
The “Kolnai” series of industrial chillers can deliver chilled water at temperatures ranging from 3°C to 30°C, with special low-temperature models capable of producing ice water as cold as –25°C (with a temperature differential of no more than ±1°C). Water-cooled chillers are available with cooling capacities from 8,514 to 163,400 kcal/h (equivalent to compressor powers from 3 to 60 HP) and are widely used across various industries. For example, in the plastics industry—particularly in injection molding and vacuum forming—chillers precisely control mold temperatures, thereby shortening cycle times, accelerating product solidification, preventing deformation and shrinkage, enhancing surface finish, and improving light transmission. They are also ideal for cooling spindle lubricating oils and hydraulic fluids in CNC machines, coordinate boring mills, grinders, machining centers, modular machine tools, and other precision machine tools, enabling precise oil-temperature control, effectively reducing thermal deformation, and improving machining accuracy. In addition, these chillers are suitable for use in electroplating, food processing, dyeing and bleaching, and other industries as well.
The “Kolnai” series of industrial chillers can deliver chilled water at temperatures ranging from 3°C to 30°C, with special low-temperature models capable of producing ice water as cold as –25°C (with a temperature differential of no more than ±1°C). Water-cooled chillers are available with cooling capacities from 8,514 to 163,400 kcal/h (equivalent to compressor powers from 3 to 60 HP) and are widely used across various industries. For example, in the plastics industry—particularly in injection molding and thermoforming—chillers precisely control mold temperatures, thereby shortening cycle times, accelerating product stabilization, preventing deformation and shrinkage, enhancing surface finish, and improving light transmission. They are also ideal for cooling spindle lubricating oils and hydraulic fluids in CNC machine tools, coordinate boring machines, grinders, machining centers, modular machine tools, and other precision equipment, enabling precise oil-temperature control, effectively reducing thermal deformation, and improving machining accuracy. In addition, these chillers are suitable for use in electroplating, food processing, dyeing and bleaching, and other industries as well.
Model
Unit
KIC-3W KIC-5W KIC-6W KIC-8W KIC-10W KIC-12W KIC-15W KIC-20W KIC-25W KIC-30W KIC-40W KIC-50W KIC-60W Cooling capacity
kcal/h 8514 13158 17028 21844 26316 32078 41108 55900 64156 83850 111800 128312 163400 Total Input Power
Keyword 9.9 15.3 19.8 25.4 30.6 37.3 47.8 65 74.6 97.5 130 149.2 190 Total Input Power
Keyword 2.5 4.04 4.57 6.03 7.33/7.68 8.16/8.51 11.32 14.56/15.26 17.02 23.59 30.12 35.14 45.5 Refrigerant
R22 Operation Control Mode
Digital Microcomputer Temperature Controller Power supply
3N, 380V, 50Hz Safety Protection Device
Overload protection, reverse phase protection, high/low voltage protection, low water flow protection, low liquid level protection, freeze protection, and more.
Compressor
Form
Fully enclosed rotary or scroll type Compressor power
Keyword 2.13 3.29 3.82 5.28 6.58 7.41 9.82 13.06 14.82 19.59 26.12 29.64 40 Condenser
Type
Shell-and-tube type (standard water-side pressure rating: 0.6 MPa to 0.8 MPa)
Water flow rate
cubic meters per hour 2.13 3.29 4.26 5.46 8.02 8.02 10.28 13.98 16.04 20.96 27.95 32.08 40.85 Plumbing connection
Inch 1 1 1 1.5 1.5 2 2 2 2.5 2.5 3 3 3 Evaporator
Type
Water-tank coil type / Dry shell-and-tube type Inlet and outlet pipe diameter
Inch 1 1 1 1.5 2 2 2 2.5 2.5 2.5 3 3 3 Water tank capacity
L 50 50 70 120 120 120 120 200 200 200 400 400 400 Pump
Traffic
L/min 40 50 50 80 80/100 80/100 150 150/200 200 300 300 500 500 Pressure
bar 1.7 1.7 1.7 1.7 1.7 1.7 1.9 2.1 2.1 2.1 2.1 2.1 2.1 Power
Keyword 0.37 0.75 0.75 0.75 0.75/1.1 0.75/1.1 1.5 1.5/2.2 2.2 4 4 5.5 5.5 External dimensions
A (long)
mm 935 935 935 1320 1320 1320 1770 1770 1770 2000 2400 2400 2400 B (width)
mm 900 900 900 650 650 650 735 735 735 1000 1000 1000 1000 C (high)
mm 500 900 900 1370 1370 1370 1610 1610 1610 1850 1800 1800 1800 Refrigerant charge
kilogram 1.7 2.8 4.5 4.4 5.6 6.8 8.4 11.2 13.6 16.8 22.4 27.2 34 Note 1: The cooling capacity is based on a chilled water inlet temperature of 15°C, an outlet temperature of 10°C, and an ambient temperature of 35°C.
2. The Company reserves the right to modify the above parameters without prior notice. Custom specifications may be designed and modified upon request.
Previous Page
Next Page
Product Details
The “Kolnai” series of industrial chillers can deliver chilled water at temperatures ranging from 3°C to 30°C, with special low-temperature models capable of producing ice water as cold as –25°C (with a temperature differential of no more than ±1°C). Water-cooled chillers are available with cooling capacities from 8,514 to 163,400 kcal/h (equivalent to compressor powers from 3 to 60 HP) and are widely used across various industries. For example, in the plastics industry—particularly in injection molding and thermoforming—chillers precisely control mold temperatures, thereby shortening cycle times, accelerating product stabilization, preventing deformation and shrinkage, enhancing surface finish, and improving light transmission. They are also ideal for cooling spindle lubricating oils and hydraulic fluids in CNC machine tools, coordinate boring machines, grinders, machining centers, modular machine tools, and other precision equipment, enabling precise oil-temperature control, effectively reducing thermal deformation, and improving machining accuracy. In addition, these chillers are suitable for use in electroplating, food processing, dyeing and bleaching, and other industries as well.
| Model |
Unit |
KIC-3W | KIC-5W | KIC-6W | KIC-8W | KIC-10W | KIC-12W | KIC-15W | KIC-20W | KIC-25W | KIC-30W | KIC-40W | KIC-50W | KIC-60W | |
| Cooling capacity |
kcal/h | 8514 | 13158 | 17028 | 21844 | 26316 | 32078 | 41108 | 55900 | 64156 | 83850 | 111800 | 128312 | 163400 | |
| Total Input Power |
Keyword | 9.9 | 15.3 | 19.8 | 25.4 | 30.6 | 37.3 | 47.8 | 65 | 74.6 | 97.5 | 130 | 149.2 | 190 | |
| Total Input Power |
Keyword | 2.5 | 4.04 | 4.57 | 6.03 | 7.33/7.68 | 8.16/8.51 | 11.32 | 14.56/15.26 | 17.02 | 23.59 | 30.12 | 35.14 | 45.5 | |
| Refrigerant |
R22 | ||||||||||||||
| Operation Control Mode |
Digital Microcomputer Temperature Controller | ||||||||||||||
| Power supply |
3N, 380V, 50Hz | ||||||||||||||
| Safety Protection Device |
Overload protection, reverse phase protection, high/low voltage protection, low water flow protection, low liquid level protection, freeze protection, and more. |
||||||||||||||
| Compressor |
Form |
Fully enclosed rotary or scroll type | |||||||||||||
| Compressor power |
Keyword | 2.13 | 3.29 | 3.82 | 5.28 | 6.58 | 7.41 | 9.82 | 13.06 | 14.82 | 19.59 | 26.12 | 29.64 | 40 | |
| Condenser |
Type |
Shell-and-tube type (standard water-side pressure rating: 0.6 MPa to 0.8 MPa) |
|||||||||||||
| Water flow rate |
cubic meters per hour | 2.13 | 3.29 | 4.26 | 5.46 | 8.02 | 8.02 | 10.28 | 13.98 | 16.04 | 20.96 | 27.95 | 32.08 | 40.85 | |
| Plumbing connection |
Inch | 1 | 1 | 1 | 1.5 | 1.5 | 2 | 2 | 2 | 2.5 | 2.5 | 3 | 3 | 3 | |
| Evaporator |
Type |
Water-tank coil type / Dry shell-and-tube type | |||||||||||||
| Inlet and outlet pipe diameter |
Inch | 1 | 1 | 1 | 1.5 | 2 | 2 | 2 | 2.5 | 2.5 | 2.5 | 3 | 3 | 3 | |
| Water tank capacity |
L | 50 | 50 | 70 | 120 | 120 | 120 | 120 | 200 | 200 | 200 | 400 | 400 | 400 | |
| Pump |
Traffic |
L/min | 40 | 50 | 50 | 80 | 80/100 | 80/100 | 150 | 150/200 | 200 | 300 | 300 | 500 | 500 |
| Pressure |
bar | 1.7 | 1.7 | 1.7 | 1.7 | 1.7 | 1.7 | 1.9 | 2.1 | 2.1 | 2.1 | 2.1 | 2.1 | 2.1 | |
| Power |
Keyword | 0.37 | 0.75 | 0.75 | 0.75 | 0.75/1.1 | 0.75/1.1 | 1.5 | 1.5/2.2 | 2.2 | 4 | 4 | 5.5 | 5.5 | |
| External dimensions |
A (long) |
mm | 935 | 935 | 935 | 1320 | 1320 | 1320 | 1770 | 1770 | 1770 | 2000 | 2400 | 2400 | 2400 |
| B (width) |
mm | 900 | 900 | 900 | 650 | 650 | 650 | 735 | 735 | 735 | 1000 | 1000 | 1000 | 1000 | |
| C (high) |
mm | 500 | 900 | 900 | 1370 | 1370 | 1370 | 1610 | 1610 | 1610 | 1850 | 1800 | 1800 | 1800 | |
| Refrigerant charge |
kilogram | 1.7 | 2.8 | 4.5 | 4.4 | 5.6 | 6.8 | 8.4 | 11.2 | 13.6 | 16.8 | 22.4 | 27.2 | 34 | |
| Note 1: The cooling capacity is based on a chilled water inlet temperature of 15°C, an outlet temperature of 10°C, and an ambient temperature of 35°C. 2. The Company reserves the right to modify the above parameters without prior notice. Custom specifications may be designed and modified upon request. |
|||||||||||||||
- Strong safety performance: Provide multiple anti-theft designs to ensure the safety of home and property.
- High durability: Made of high-quality materials, corrosion-resistant and wear-resistant, with a long service life.
- Appearance diversity: Rich design styles, perfect match with various decorations.
- Easy operation: Intelligent design, no key required, simple and efficient to use.
- Multifunctionality: With alarm prompts and networking functions, it meets the needs of multiple scenarios.
- Easy installation: Compatible with a variety of door types, quick installation, and strong adaptability.
Certificate
FAQ
Q
What are the common reasons for the mold temperature controller alarming and shutting down?
A
Common reasons include high-temperature protection, low liquid level alarm, overload protection, heating element failure, or pump malfunction.
Q
Why is the cooling performance of the chiller poor?
A
Possible causes include insufficient refrigerant, blocked condenser, compressor failure, or pipeline leakage. Inspections and repairs are needed.
Q
What is the working principle of a mold temperature controller (MTC)?
A
The MTC heats or cools the medium (such as water or thermal oil) to a set temperature and then circulates it through the mold or equipment via a pump to achieve precise temperature control.
Q
Why is the mold temperature controller heating up slowly?
A
Possible reasons include insufficient heating power, pump failure, pipeline blockage, or insufficient medium. These should be checked and resolved step by step.
Q
What is the difference between a mold temperature controller and a chiller?
A
The MTC is used for heating and maintaining the temperature of equipment or molds, while the chiller is mainly used for quickly cooling equipment or molds to lower the temperature.
Contact
Fax: 86-750-3609612
Add: No. 38, Yecheng Industrial Zone, Kautou Star Village, Jianghai District, Jiangmen, Guangdong, China