- Commodity name: Air-cooled chiller
The Keernai brand series of industrial chillers can deliver temperatures ranging from 3°C to 30°C, with specialized low-temperature models capable of reaching below -25°C, producing chilled water with a temperature tolerance of no more than ±1°C.
The Keernai brand series of industrial chillers operate within a temperature range of 3–30°C, with special low-temperature models capable of delivering chilled water at temperatures as low as –25°C (with temperature control accuracy of ±1°C). Air-cooled chillers offer cooling capacities ranging from 7,482 to 154,800 kcal/h (driven by compressors rated from 3 to 60 HP) and are widely applicable across various industries. For instance, in plastic injection molding, these chillers enable precise control of mold temperature, thereby shortening cycle times, accelerating production rates, preventing product deformation and shrinkage, improving surface finish, and enhancing transparency. They are also suitable for cooling the spindle lubrication and hydraulic fluid of CNC machines, boring mills, grinding machines, machining centers, precision machine tools, and various multi-axis machine tools, allowing accurate oil temperature control, reducing thermal distortion, and improving machining accuracy. Additionally, they find applications in other sectors such as electroplating, food processing, and dyeing.
Model Project Unit KIC-3W KIC-5W KIC-6W KIC-&W KIC-10W KIC-12W KIC-15W KIC-20W KIC-25W KIC-30W KIC-40W KIC-50W KIC-60W Cooling capacity kcal/h 8514 13158 17028 21844 26316 32078 41108 55900 64156 83850 111800 128312 163400 Keyword 9.9 15.3 19.8 25.4 30.6 373 47.8 65 74.6 97.5 130 1492 190 Total Power Input Keyword 2.5 4.04 4.57 6.03 7.33/7.68 8.16/8.51 11.32 14.56/15.26 17.02 23.59 30.12 35.14 45.5 Refrigerant R22 Operation Control Mode Digital display microcomputer temperature control unit Power supply 3N, 380V, 50HZ Safety Protection Device Overload protection, reverse/phase-loss protection, high/low-pressure protection, low-water-flow protection, low-water-level protection, freeze protection, and more. Compressor Type Closed rotor or scroll Compressor power Keyword 2.13 3.29 3.82 5.28 6.58 Z41 9.82 1306 14.82 19.59 26.12 29.64 40 Condenser Type Shell-and-tube (standard pressure on the water side): 0.6 MPa to 0.8 MPa Water flow rate m3/h 2.13 329 4.26 5.46 6.58 8.02 1028 13.98 16.04 20.96 27.95 32.08 40.85 Pipe fitting inch 1 1 1 1.5 1.5 2 2 2 2.5 2.5 3 3 3 Evaporator Type Water tank coil/dry shell-and-tube Inlet/Outlet Pipe Diameter inch 1 1 1 1.5 2 2 2 2.5 2.5 2.5 3 3 3 Water tank capacity L 50 50 70 120 120 120 120 200 200 200 400 400 400 pump Traffic L/min 40 50 50 80 80/100 80/100 150 150/200 200 300 300 500 500 Pressure bar 1.7 1.7 1.7 1.7 1.7 1.7 1.9 2J Z1 2.1 2.1 2.1 2.1 Power Keyword 0.37 0.75 0.75 0.75 0.75/1.1 0.75/1.1 1.5 1.5/2^ 22 4 4 5.5 5.5 External dimensions A (length) mm 935 935 935 1320 1320 1320 1770 1770 1770 2000 2400 2400 2400 B (width) mm 500 500 500 650 650 650 735 735 735 1000 1000 1000 1000 C (height) mm 900 900 900 1370 1370 1370 1610 1610 1610 1850 1800 1800 1800 Refrigerant Charging Capacity kilogram 1.7 2.8 4.5 4.4 5.6 6l8 8.4 112 13.6 16.8 22.4 27.2 34 1. The above parameters are based on a cooling water inlet/outlet temperature of 15°C/10°C and an ambient temperature of 35°C.
2. The company reserves the right to modify the aforementioned parameters without prior notice. Custom specifications may be modified on a case-by-case basis.
Previous Page
Next Page
Product Details
The Keernai brand series of industrial chillers operate within a temperature range of 3–30°C, with special low-temperature models capable of delivering chilled water at temperatures as low as –25°C (with temperature control accuracy of ±1°C). Air-cooled chillers offer cooling capacities ranging from 7,482 to 154,800 kcal/h (driven by compressors rated from 3 to 60 HP) and are widely applicable across various industries. For instance, in plastic injection molding, these chillers enable precise control of mold temperature, thereby shortening cycle times, accelerating production rates, preventing product deformation and shrinkage, improving surface finish, and enhancing transparency. They are also suitable for cooling the spindle lubrication and hydraulic fluid of CNC machines, boring mills, grinding machines, machining centers, precision machine tools, and various multi-axis machine tools, allowing accurate oil temperature control, reducing thermal distortion, and improving machining accuracy. Additionally, they find applications in other sectors such as electroplating, food processing, and dyeing.
| Model | |||||||||||||||
| Project | Unit | KIC-3W | KIC-5W | KIC-6W | KIC-&W | KIC-10W | KIC-12W | KIC-15W | KIC-20W | KIC-25W | KIC-30W | KIC-40W | KIC-50W | KIC-60W | |
| Cooling capacity | kcal/h | 8514 | 13158 | 17028 | 21844 | 26316 | 32078 | 41108 | 55900 | 64156 | 83850 | 111800 | 128312 | 163400 | |
| Keyword | 9.9 | 15.3 | 19.8 | 25.4 | 30.6 | 373 | 47.8 | 65 | 74.6 | 97.5 | 130 | 1492 | 190 | ||
| Total Power Input | Keyword | 2.5 | 4.04 | 4.57 | 6.03 | 7.33/7.68 | 8.16/8.51 | 11.32 | 14.56/15.26 | 17.02 | 23.59 | 30.12 | 35.14 | 45.5 | |
| Refrigerant | R22 | ||||||||||||||
| Operation Control Mode | Digital display microcomputer temperature control unit | ||||||||||||||
| Power supply | 3N, 380V, 50HZ | ||||||||||||||
| Safety Protection Device | Overload protection, reverse/phase-loss protection, high/low-pressure protection, low-water-flow protection, low-water-level protection, freeze protection, and more. | ||||||||||||||
| Compressor | Type | Closed rotor or scroll | |||||||||||||
| Compressor power | Keyword | 2.13 | 3.29 | 3.82 | 5.28 | 6.58 | Z41 | 9.82 | 1306 | 14.82 | 19.59 | 26.12 | 29.64 | 40 | |
| Condenser | Type | Shell-and-tube (standard pressure on the water side): 0.6 MPa to 0.8 MPa | |||||||||||||
| Water flow rate | m3/h | 2.13 | 329 | 4.26 | 5.46 | 6.58 | 8.02 | 1028 | 13.98 | 16.04 | 20.96 | 27.95 | 32.08 | 40.85 | |
| Pipe fitting | inch | 1 | 1 | 1 | 1.5 | 1.5 | 2 | 2 | 2 | 2.5 | 2.5 | 3 | 3 | 3 | |
| Evaporator | Type | Water tank coil/dry shell-and-tube | |||||||||||||
| Inlet/Outlet Pipe Diameter | inch | 1 | 1 | 1 | 1.5 | 2 | 2 | 2 | 2.5 | 2.5 | 2.5 | 3 | 3 | 3 | |
| Water tank capacity | L | 50 | 50 | 70 | 120 | 120 | 120 | 120 | 200 | 200 | 200 | 400 | 400 | 400 | |
| pump | Traffic | L/min | 40 | 50 | 50 | 80 | 80/100 | 80/100 | 150 | 150/200 | 200 | 300 | 300 | 500 | 500 |
| Pressure | bar | 1.7 | 1.7 | 1.7 | 1.7 | 1.7 | 1.7 | 1.9 | 2J | Z1 | 2.1 | 2.1 | 2.1 | 2.1 | |
| Power | Keyword | 0.37 | 0.75 | 0.75 | 0.75 | 0.75/1.1 | 0.75/1.1 | 1.5 | 1.5/2^ | 22 | 4 | 4 | 5.5 | 5.5 | |
| External dimensions | A (length) | mm | 935 | 935 | 935 | 1320 | 1320 | 1320 | 1770 | 1770 | 1770 | 2000 | 2400 | 2400 | 2400 |
| B (width) | mm | 500 | 500 | 500 | 650 | 650 | 650 | 735 | 735 | 735 | 1000 | 1000 | 1000 | 1000 | |
| C (height) | mm | 900 | 900 | 900 | 1370 | 1370 | 1370 | 1610 | 1610 | 1610 | 1850 | 1800 | 1800 | 1800 | |
| Refrigerant Charging Capacity | kilogram | 1.7 | 2.8 | 4.5 | 4.4 | 5.6 | 6l8 | 8.4 | 112 | 13.6 | 16.8 | 22.4 | 27.2 | 34 | |
| 1. The above parameters are based on a cooling water inlet/outlet temperature of 15°C/10°C and an ambient temperature of 35°C. 2. The company reserves the right to modify the aforementioned parameters without prior notice. Custom specifications may be modified on a case-by-case basis. |
|||||||||||||||
- Strong safety performance: Provide multiple anti-theft designs to ensure the safety of home and property.
- High durability: Made of high-quality materials, corrosion-resistant and wear-resistant, with a long service life.
- Appearance diversity: Rich design styles, perfect match with various decorations.
- Easy operation: Intelligent design, no key required, simple and efficient to use.
- Multifunctionality: With alarm prompts and networking functions, it meets the needs of multiple scenarios.
- Easy installation: Compatible with a variety of door types, quick installation, and strong adaptability.
Certificate
FAQ
Q
What are the common reasons for the mold temperature controller alarming and shutting down?
A
Common reasons include high-temperature protection, low liquid level alarm, overload protection, heating element failure, or pump malfunction.
Q
Why is the cooling performance of the chiller poor?
A
Possible causes include insufficient refrigerant, blocked condenser, compressor failure, or pipeline leakage. Inspections and repairs are needed.
Q
What is the working principle of a mold temperature controller (MTC)?
A
The MTC heats or cools the medium (such as water or thermal oil) to a set temperature and then circulates it through the mold or equipment via a pump to achieve precise temperature control.
Q
Why is the mold temperature controller heating up slowly?
A
Possible reasons include insufficient heating power, pump failure, pipeline blockage, or insufficient medium. These should be checked and resolved step by step.
Q
What is the difference between a mold temperature controller and a chiller?
A
The MTC is used for heating and maintaining the temperature of equipment or molds, while the chiller is mainly used for quickly cooling equipment or molds to lower the temperature.