- Commodity name: Standard dryer
Machine Model KGZ-12A KGZ-25A KGZ-50A KGZ-75A KGZ-100A KGZ-150A KGZ-200A KGZ-300A KGZ-400A KGZ-500A KGZ-600A KGZ-800A KGZ-1000A Hopper Capacity (kg) 12 25 50 75 100 150 200 300 400 500 600 800 1000 Electric heating power (kW) 1.8 3.5 4.5 5.2 6 9 12 15 18 18 21 24 27 Power Supply Voltage (V) 220 220 380 380 380 380 380 380 380 380 380 380 380 Fan power (W) 75 135 155 155 215 215 320 320 340 340 1100 1500 1500 Fan flange (mm) 100 120 120 120 150 150 190 190 220 220 230 183 183 H (mm) 805 996 1163 1263 1326 1552 1680 1855 1941 1890 2080 2620 2820 H1 (mm) 787 939 1063 1120 1204 1295 1550 1592 1730 1740 2295 2320 2320 H2 (mm) 319 399 478 478 539 539 605 650 660 711 815 920 920 H3 (mm) 380 462 550 650 650 853 915 1020 1045 1045 1265 1460 1466 H4 (mm) 162 205 220 222 255 248 290 280 290 285 355 400 400 H5 (mm) 107 259 158 158 174 174 190 195 205 205 245 270 270 H6 (mm) 212 245 320 320 365 365 415 455 506 455 570 660 660 w (mm) 655 750 860 885 1005 1040 1210 1270 1360 1425 1580 1770 1770 D (mm) 340 400 470 555 600 640 770 835 925 975 1070 1170 1170 D1 (mm) 108 249 157 157 176 176 230 230 280 280 280 280 280 W1 (mm) 108 249 157 157 176 176 230 230 280 280 280 280 280 φ A (mm) 330 390 463 535 640 640 750 815 900 950 1050 1150 1150 φ B (mm) 45 60 75 75 80 80 110 110 115 115 135 135 135 Net weight (kg) 25 34 40 46 60 80 100 140 185 198 270 380 395 Package volume (m³) 0.2 0.29 0.4 0.51 0.7 0.93 1.43 1.94 2.27 2.47 3.7 5.3 7.8 Package dimensions (cm) 70x43x72 75x46x84 87x49x97 89x55x104 102x63x109 107x67x129 120x83x143 129x94x164 138x98x168 145x103x165 164x114x198 180x126x230 180x126x249 ※The machine is designed for standard domestic voltage and can be customized for non-standard voltages used in other countries.
Optional accessories: L-shaped tripod, A-shaped tripod, material suction box, magnetic holder, magnetic base, sliding plate, hot-air recovery filter, dust collector
The above specifications are subject to change without prior notice. Custom specifications can be designed and manufactured upon request.
※The machine’s standard domestic voltage can be customized to meet foreign non-standard special voltage requirements.
Optional devices: L-shaped tripod, A-shaped tripod, suction box, magnetic frame, magnetic base, slide plate, hot air recovery filter, dust collector
The above specifications are subject to change without notice. Special specifications can be designed and manufactured separately.
Previous Page
Product Details
| Machine Model | KGZ-12A | KGZ-25A | KGZ-50A | KGZ-75A | KGZ-100A | KGZ-150A | KGZ-200A | KGZ-300A | KGZ-400A | KGZ-500A | KGZ-600A | KGZ-800A | KGZ-1000A |
| Hopper Capacity (kg) | 12 | 25 | 50 | 75 | 100 | 150 | 200 | 300 | 400 | 500 | 600 | 800 | 1000 |
| Electric heating power (kW) | 1.8 | 3.5 | 4.5 | 5.2 | 6 | 9 | 12 | 15 | 18 | 18 | 21 | 24 | 27 |
| Power Supply Voltage (V) | 220 | 220 | 380 | 380 | 380 | 380 | 380 | 380 | 380 | 380 | 380 | 380 | 380 |
| Fan power (W) | 75 | 135 | 155 | 155 | 215 | 215 | 320 | 320 | 340 | 340 | 1100 | 1500 | 1500 |
| Fan flange (mm) | 100 | 120 | 120 | 120 | 150 | 150 | 190 | 190 | 220 | 220 | 230 | 183 | 183 |
| H (mm) | 805 | 996 | 1163 | 1263 | 1326 | 1552 | 1680 | 1855 | 1941 | 1890 | 2080 | 2620 | 2820 |
| H1 (mm) | 787 | 939 | 1063 | 1120 | 1204 | 1295 | 1550 | 1592 | 1730 | 1740 | 2295 | 2320 | 2320 |
| H2 (mm) | 319 | 399 | 478 | 478 | 539 | 539 | 605 | 650 | 660 | 711 | 815 | 920 | 920 |
| H3 (mm) | 380 | 462 | 550 | 650 | 650 | 853 | 915 | 1020 | 1045 | 1045 | 1265 | 1460 | 1466 |
| H4 (mm) | 162 | 205 | 220 | 222 | 255 | 248 | 290 | 280 | 290 | 285 | 355 | 400 | 400 |
| H5 (mm) | 107 | 259 | 158 | 158 | 174 | 174 | 190 | 195 | 205 | 205 | 245 | 270 | 270 |
| H6 (mm) | 212 | 245 | 320 | 320 | 365 | 365 | 415 | 455 | 506 | 455 | 570 | 660 | 660 |
| w (mm) | 655 | 750 | 860 | 885 | 1005 | 1040 | 1210 | 1270 | 1360 | 1425 | 1580 | 1770 | 1770 |
| D (mm) | 340 | 400 | 470 | 555 | 600 | 640 | 770 | 835 | 925 | 975 | 1070 | 1170 | 1170 |
| D1 (mm) | 108 | 249 | 157 | 157 | 176 | 176 | 230 | 230 | 280 | 280 | 280 | 280 | 280 |
| W1 (mm) | 108 | 249 | 157 | 157 | 176 | 176 | 230 | 230 | 280 | 280 | 280 | 280 | 280 |
| φ A (mm) | 330 | 390 | 463 | 535 | 640 | 640 | 750 | 815 | 900 | 950 | 1050 | 1150 | 1150 |
| φ B (mm) | 45 | 60 | 75 | 75 | 80 | 80 | 110 | 110 | 115 | 115 | 135 | 135 | 135 |
| Net weight (kg) | 25 | 34 | 40 | 46 | 60 | 80 | 100 | 140 | 185 | 198 | 270 | 380 | 395 |
| Package volume (m³) | 0.2 | 0.29 | 0.4 | 0.51 | 0.7 | 0.93 | 1.43 | 1.94 | 2.27 | 2.47 | 3.7 | 5.3 | 7.8 |
| Package dimensions (cm) | 70x43x72 | 75x46x84 | 87x49x97 | 89x55x104 | 102x63x109 | 107x67x129 | 120x83x143 | 129x94x164 | 138x98x168 | 145x103x165 | 164x114x198 | 180x126x230 | 180x126x249 |
| ※The machine is designed for standard domestic voltage and can be customized for non-standard voltages used in other countries. Optional accessories: L-shaped tripod, A-shaped tripod, material suction box, magnetic holder, magnetic base, sliding plate, hot-air recovery filter, dust collector The above specifications are subject to change without prior notice. Custom specifications can be designed and manufactured upon request. ※The machine’s standard domestic voltage can be customized to meet foreign non-standard special voltage requirements. Optional devices: L-shaped tripod, A-shaped tripod, suction box, magnetic frame, magnetic base, slide plate, hot air recovery filter, dust collector The above specifications are subject to change without notice. Special specifications can be designed and manufactured separately. |
|||||||||||||
- Strong safety performance: Provide multiple anti-theft designs to ensure the safety of home and property.
- High durability: Made of high-quality materials, corrosion-resistant and wear-resistant, with a long service life.
- Appearance diversity: Rich design styles, perfect match with various decorations.
- Easy operation: Intelligent design, no key required, simple and efficient to use.
- Multifunctionality: With alarm prompts and networking functions, it meets the needs of multiple scenarios.
- Easy installation: Compatible with a variety of door types, quick installation, and strong adaptability.
Certificate
FAQ
Q
Why does the oil temperature machine catch fire?
A
The fire situation of the oil temperature machine can be divided into two types: 1. The heat transfer oil itself is not touched by other items and spontaneous combustion occurs. Reason: A. The temperature of the heat transfer oil reaches the ignition point and catches fire in contact with air. B. The temperature of the heat transfer oil reaches the flash point and the volatile gas in the oil tank reaches a certain concentration.
Q
In industrial applications, air-cooled chiller refrigeration compressor protection devices have what role?
A
In industrial applications, chilled water or other liquid cooling is pumped through process or laboratory equipment. Chillers are used to control the cooling of products, mechanisms and plant machinery in all walks of life. They are commonly used in the plastics industry for injection and blow molding, metal processing and cutting.
Q
What are the application fields and functions of ultra-high temperature mold temperature machine
A
Ultra-high temperature mold temperature machine is a type of equipment classified according to the temperature control range of the mold temperature machine, corresponding to ordinary mold temperature machine and high temperature mold temperature machine, etc. Due to the different circulating heating media used, it is divided into two types: oil circulating mold temperature machine and water circulating mold temperature machine.
Q
How to extend the service life of high temperature oil mold temperature machine?
A
The application of mold temperature machine in various industries is very common. The equipment uses water or heat transfer oil as heat transfer medium. Through PID self-tuning adjustment method, the temperature of the application equipment can be accurately controlled.
Q
Why does the cold water machine have high pressure failure
A
Several common faults of cold water machine compressor briefly summarizes the common cold water machine fault problems, which can be roughly divided into four categories: 1. compressor fault: 1. first check whether the compressor can start normally, and measure whether the compressor voltage is normal.
Contact
Fax: 86-750-3609612
Add: No. 38, Yecheng Industrial Zone, Kautou Star Village, Jianghai District, Jiangmen, Guangdong, China