- Product Description
- Specifications
-
- Commodity name: High-temperature water chiller
◆ Oil-blowing and oil-return function (optional) ◆ Oil-return temperature display (optional) ◆ Automatic air-venting upon power-up ◆ Heating-power switching function ◆ Instant cooling and shutdown function (optional) ◆ RS485 communication interface for automated management (optional) ◆ Hot-oil BY-PASS pressure-relief circuit ◆ Multi-point temperature-control units available as custom orders ◆ Oil-pump horsepower and heating power customizable ◆ Electrical components from SIEMENS, Weidmuller, LS, JUMO, ABB, and WEST (optional) ◆ Temperature control range: inlet water temperature +45°C to 180°C ◆ Control method: imported microcomputer control or (optional) PLC control ◆ Comprehensive safety protection with fault indication; maintenance and servicing require no specialized personnel
◆ Blow-Back Oil Recovery Function (Optional)
◆ Oil return temperature display (optional)
◆ Automatic air venting upon power-up
◆ Heating Power Switching Function
◆Instant Cooling Shutdown Function (Optional)
◆ RS485 communication function for automated management (optional)
◆Hot Oil BY-PASS Pressure-Relief Circuit
◆ Multi-point temperature control units are available for custom order.
◆ Oil pump horsepower and heating power can be customized.
◆Electrical components from SIEMENS, Weidmuller, LS, JUMO, ABB, and WEST (optional).
◆ Temperature control range: Inlet water temperature +45℃ to -180℃
◆Control Method: Employs an imported microcomputer or (optional) PLC control.
◆ Comprehensive safety protection, fault display, and no need for professional personnel for repair and maintenance.Project Unit KT-600 KT-900 KT-1200 KT-1800 KT-2400 KT-3600 Temperature control range degrees Celsius Inlet water temperature: +45℃ to -180℃ Temperature control accuracy degrees Celsius PID ±1℃ Power supply AC 3-phase 380 V 50 Hz (3-phase + Earth); AC 3-phase 440 V 60 Hz; AC 3-phase 460 V 60 Hz Heat transfer medium Heat transfer oil Cooling method Indirect cooling Heating capacity Keyword 6 9 12 9+9 12+12 18+18 Pump horsepower hp 0.5 1 1 2 2 3 Pump flow L/min 42 56 56 110(200) 110(200) 140(300) Pump pressure kg/cm² 1.5 2 2 3(2) 3(2) 4(2) Maximum Power Consumption Keyword 6.5 10 13 20 26 39 Alarm Function Phase loss / Oil shortage / Overload / Oil overflow / Abnormal heating alarm Cooling water piping inch 1/2 1/2 1/2 1/2 1/2 1/2 Circulating Oil Piping inch 3/8 × 2 3/8 × 4 3/8 × 4 3/8 × 4 3/8 × 6 3/8 × 8 Overall Reference Dimensions mm 840×320×660 840×320×660 840×320×660 940×340×860 940×340×860 940×340×860 The above specifications are subject to change without prior notice; custom designs and modifications can be provided for special requirements.
Product Details
◆ Blow-Back Oil Recovery Function (Optional)
◆ Oil return temperature display (optional)
◆ Automatic air venting upon power-up
◆ Heating Power Switching Function
◆Instant Cooling Shutdown Function (Optional)
◆ RS485 communication function for automated management (optional)
◆Hot Oil BY-PASS Pressure-Relief Circuit
◆ Multi-point temperature control units are available for custom order.
◆ Oil pump horsepower and heating power can be customized.
◆Electrical components from SIEMENS, Weidmuller, LS, JUMO, ABB, and WEST (optional).
◆ Temperature control range: Inlet water temperature +45℃ to -180℃
◆Control Method: Employs an imported microcomputer or (optional) PLC control.
◆ Comprehensive safety protection, fault display, and no need for professional personnel for repair and maintenance.
| Project | Unit | KT-600 | KT-900 | KT-1200 | KT-1800 | KT-2400 | KT-3600 |
| Temperature control range | degrees Celsius | Inlet water temperature: +45℃ to -180℃ | |||||
| Temperature control accuracy | degrees Celsius | PID ±1℃ | |||||
| Power supply | AC 3-phase 380 V 50 Hz (3-phase + Earth); AC 3-phase 440 V 60 Hz; AC 3-phase 460 V 60 Hz | ||||||
| Heat transfer medium | Heat transfer oil | ||||||
| Cooling method | Indirect cooling | ||||||
| Heating capacity | Keyword | 6 | 9 | 12 | 9+9 | 12+12 | 18+18 |
| Pump horsepower | hp | 0.5 | 1 | 1 | 2 | 2 | 3 |
| Pump flow | L/min | 42 | 56 | 56 | 110(200) | 110(200) | 140(300) |
| Pump pressure | kg/cm² | 1.5 | 2 | 2 | 3(2) | 3(2) | 4(2) |
| Maximum Power Consumption | Keyword | 6.5 | 10 | 13 | 20 | 26 | 39 |
| Alarm Function | Phase loss / Oil shortage / Overload / Oil overflow / Abnormal heating alarm | ||||||
| Cooling water piping | inch | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 |
| Circulating Oil Piping | inch | 3/8 × 2 | 3/8 × 4 | 3/8 × 4 | 3/8 × 4 | 3/8 × 6 | 3/8 × 8 |
| Overall Reference Dimensions | mm | 840×320×660 | 840×320×660 | 840×320×660 | 940×340×860 | 940×340×860 | 940×340×860 |
| The above specifications are subject to change without prior notice; custom designs and modifications can be provided for special requirements. | |||||||
- Strong safety performance: Provide multiple anti-theft designs to ensure the safety of home and property.
- High durability: Made of high-quality materials, corrosion-resistant and wear-resistant, with a long service life.
- Appearance diversity: Rich design styles, perfect match with various decorations.
- Easy operation: Intelligent design, no key required, simple and efficient to use.
- Multifunctionality: With alarm prompts and networking functions, it meets the needs of multiple scenarios.
- Easy installation: Compatible with a variety of door types, quick installation, and strong adaptability.
Certificate
FAQ
Q
Why does the oil temperature machine catch fire?
A
The fire situation of the oil temperature machine can be divided into two types: 1. The heat transfer oil itself is not touched by other items and spontaneous combustion occurs. Reason: A. The temperature of the heat transfer oil reaches the ignition point and catches fire in contact with air. B. The temperature of the heat transfer oil reaches the flash point and the volatile gas in the oil tank reaches a certain concentration.
Q
In industrial applications, air-cooled chiller refrigeration compressor protection devices have what role?
A
In industrial applications, chilled water or other liquid cooling is pumped through process or laboratory equipment. Chillers are used to control the cooling of products, mechanisms and plant machinery in all walks of life. They are commonly used in the plastics industry for injection and blow molding, metal processing and cutting.
Q
What are the application fields and functions of ultra-high temperature mold temperature machine
A
Ultra-high temperature mold temperature machine is a type of equipment classified according to the temperature control range of the mold temperature machine, corresponding to ordinary mold temperature machine and high temperature mold temperature machine, etc. Due to the different circulating heating media used, it is divided into two types: oil circulating mold temperature machine and water circulating mold temperature machine.
Q
How to extend the service life of high temperature oil mold temperature machine?
A
The application of mold temperature machine in various industries is very common. The equipment uses water or heat transfer oil as heat transfer medium. Through PID self-tuning adjustment method, the temperature of the application equipment can be accurately controlled.
Q
Why does the cold water machine have high pressure failure
A
Several common faults of cold water machine compressor briefly summarizes the common cold water machine fault problems, which can be roughly divided into four categories: 1. compressor fault: 1. first check whether the compressor can start normally, and measure whether the compressor voltage is normal.
Contact
Fax: 86-750-3609612
Add: No. 38, Yecheng Industrial Zone, Kautou Star Village, Jianghai District, Jiangmen, Guangdong, China