◆Explosion-proof device (optional) ◆Oil return temperature display (optional) ◆Automatic air venting upon power-up ◆Oil pump back-suction oil return function (optional) ◆Heating power switching function ◆Isolated electrical control cabinet to extend the service life of electrical components ◆RS485 communication interface for automated management (optional) ◆Instant cooling and oil return upon power-up ◆Hot oil BY-PASS pressure relief circuit ◆Customizable oil pump horsepower and heating power ◆All models equipped with magnetic drive pumps, ensuring zero oil leakage ◆All models use electrical components from European and American brands ◆Electrical components from SIEMENS, Weidmuller, LS, JUMO, ABB, and WEST (optional) ◆Temperature control range: inlet water temperature +45°C to 320°C ◆Control method: imported microcomputer control or (optional) PLC control ◆Comprehensive safety protection, fault display, and maintenance/repair that can be performed without specialized personnel

隐藏域元素占位

Keywords

  • Product Description
  • Specifications
    • Commodity name: Die-casting-specific oil temperature controller

    ◆Explosion-proof device (optional) ◆Oil return temperature display (optional) ◆Automatic air venting upon power-up ◆Oil pump back-suction oil return function (optional) ◆Heating power switching function ◆Isolated electrical control cabinet to extend the service life of electrical components ◆RS485 communication interface for automated management (optional) ◆Instant cooling and oil return upon power-up ◆Hot oil BY-PASS pressure relief circuit ◆Customizable oil pump horsepower and heating power ◆All models equipped with magnetic drive pumps, ensuring zero oil leakage ◆All models use electrical components from European and American brands ◆Electrical components from SIEMENS, Weidmuller, LS, JUMO, ABB, and WEST (optional) ◆Temperature control range: inlet water temperature +45°C to 320°C ◆Control method: imported microcomputer control or (optional) PLC control ◆Comprehensive safety protection, fault display, and maintenance/repair that can be performed without specialized personnel

    ◆Explosion-proof device (optional)
    ◆ Oil return temperature display (optional)
    ◆ Automatic air venting upon power-up
    ◆ Oil pump back-suction oil return function (optional)
    ◆ Heating Power Switching Function
    ◆ Isolated electrical control box, extending the service life of electrical equipment
    ◆ RS485 communication function for automated management (optional)
    ◆Instant Cooling and Oil Return Startup Function
    ◆Hot Oil BY-PASS Pressure-Relief Circuit
    ◆ Oil pump horsepower and heating power can be customized.
    ◆The entire series features magnetic drive pumps, ensuring zero oil leakage.
    ◆All electrical components in the entire product line are sourced from European and American brands.
    ◆Electrical components are sourced from SIEMENS, Weidmuller, LS, JUMO, ABB, and WEST (optional).
    ◆ Temperature control range: Inlet water temperature +45℃ to -320℃
    ◆Control Method: Employs an imported microcomputer or (optional) PLC control.
    ◆ Comprehensive safety protection, fault display, and no need for professional personnel for repair and maintenance.

    Project Unit KTC-18YZ KTC-30YZ KTC-40YZ KTC-18YZD KTC-36YZD KTC-48YZD
    Rated Outlet Temperature degrees Celsius Inlet water temperature: +45℃ to -320℃
    Temperature control accuracy degrees Celsius PID ±1℃
    Power supply / 3P AC 380V/480V 50Hz (3-phase + Earth)
    Heat transfer medium / Heat transfer oil
    Cooling method / Indirect cooling
    Cooling area square meters 0.36 0.36 0.48 0.36 + 0.36 0.36 + 0.36 0.48 + 0.48
    Expansion tank capacity L 25 30 30 40 40 50
    Heating power Keyword 9 times 2 15 times 2 20×2 18+18 30+30 40+40
    Pump power Keyword 0.5 1 2.8 0.5+0.5 1+1 2.8 + 2.8
    Maximum pump flow L/min 25.5 55 140 25.5+25.5 55+55 140+140
    Maximum Power Consumption Keyword 19 32 43 37 63 86
    Special Features / Pump reversal and oil return
    Alarm Function / Reverse Phase / Oil Shortage / Overtemperature / Overload / Heating Abnormality Alarm
    Cooling water piping inch 1/2" 1/2" 1/2" 3/4 inch 3/4 inch 3/4 inch
    Circulating Oil Piping inch 3/4 inch 3/4 inch 1" 3/4"+3/4" 3/4"+3/4" 1"+1"
    Overall Reference Dimensions mm 1220×400×1160 1600×500×1360 1720×650×1450
    Note: 1. Cooling water flow rate: 20 L/min (30°C, 1 kg/cm²); media flow rate: 50–100 L/min.
    2. The above cooling oil temperature is 200°C.
    The above specifications are subject to change without prior notice; custom designs and modifications can be provided for special requirements.

Previous Page

Next Page

Product Details

◆Explosion-proof device (optional)
◆ Oil return temperature display (optional)
◆ Automatic air venting upon power-up
◆ Oil pump back-suction oil return function (optional)
◆ Heating Power Switching Function
◆ Isolated electrical control box, extending the service life of electrical equipment
◆ RS485 communication function for automated management (optional)
◆Instant Cooling and Oil Return Startup Function
◆Hot Oil BY-PASS Pressure-Relief Circuit
◆ Oil pump horsepower and heating power can be customized.
◆The entire series features magnetic drive pumps, ensuring zero oil leakage.
◆All electrical components in the entire product line are sourced from European and American brands.
◆Electrical components are sourced from SIEMENS, Weidmuller, LS, JUMO, ABB, and WEST (optional).
◆ Temperature control range: Inlet water temperature +45℃ to -320℃
◆Control Method: Employs an imported microcomputer or (optional) PLC control.
◆ Comprehensive safety protection, fault display, and no need for professional personnel for repair and maintenance.

Project Unit KTC-18YZ KTC-30YZ KTC-40YZ KTC-18YZD KTC-36YZD KTC-48YZD
Rated Outlet Temperature degrees Celsius Inlet water temperature: +45℃ to -320℃
Temperature control accuracy degrees Celsius PID ±1℃
Power supply / 3P AC 380V/480V 50Hz (3-phase + Earth)
Heat transfer medium / Heat transfer oil
Cooling method / Indirect cooling
Cooling area square meters 0.36 0.36 0.48 0.36 + 0.36 0.36 + 0.36 0.48 + 0.48
Expansion tank capacity L 25 30 30 40 40 50
Heating power Keyword 9 times 2 15 times 2 20×2 18+18 30+30 40+40
Pump power Keyword 0.5 1 2.8 0.5+0.5 1+1 2.8 + 2.8
Maximum pump flow L/min 25.5 55 140 25.5+25.5 55+55 140+140
Maximum Power Consumption Keyword 19 32 43 37 63 86
Special Features / Pump reversal and oil return
Alarm Function / Reverse Phase / Oil Shortage / Overtemperature / Overload / Heating Abnormality Alarm
Cooling water piping inch 1/2" 1/2" 1/2" 3/4 inch 3/4 inch 3/4 inch
Circulating Oil Piping inch 3/4 inch 3/4 inch 1" 3/4"+3/4" 3/4"+3/4" 1"+1"
Overall Reference Dimensions mm 1220×400×1160 1600×500×1360 1720×650×1450
Note: 1. Cooling water flow rate: 20 L/min (30°C, 1 kg/cm²); media flow rate: 50–100 L/min.
2. The above cooling oil temperature is 200°C.
The above specifications are subject to change without prior notice; custom designs and modifications can be provided for special requirements.
  • Strong safety performance: Provide multiple anti-theft designs to ensure the safety of home and property.
  • High durability: Made of high-quality materials, corrosion-resistant and wear-resistant, with a long service life.
  • Appearance diversity: Rich design styles, perfect match with various decorations.
  • Easy operation: Intelligent design, no key required, simple and efficient to use.
  • Multifunctionality: With alarm prompts and networking functions, it meets the needs of multiple scenarios.
  • Easy installation: Compatible with a variety of door types, quick installation, and strong adaptability.

Certificate


Certificate
Certificate
Certificate

FAQ


Q

Why does the oil temperature machine catch fire?


A

The fire situation of the oil temperature machine can be divided into two types: 1. The heat transfer oil itself is not touched by other items and spontaneous combustion occurs. Reason: A. The temperature of the heat transfer oil reaches the ignition point and catches fire in contact with air. B. The temperature of the heat transfer oil reaches the flash point and the volatile gas in the oil tank reaches a certain concentration.

Q

In industrial applications, air-cooled chiller refrigeration compressor protection devices have what role?


A

In industrial applications, chilled water or other liquid cooling is pumped through process or laboratory equipment. Chillers are used to control the cooling of products, mechanisms and plant machinery in all walks of life. They are commonly used in the plastics industry for injection and blow molding, metal processing and cutting.

Q

What are the application fields and functions of ultra-high temperature mold temperature machine


A

Ultra-high temperature mold temperature machine is a type of equipment classified according to the temperature control range of the mold temperature machine, corresponding to ordinary mold temperature machine and high temperature mold temperature machine, etc. Due to the different circulating heating media used, it is divided into two types: oil circulating mold temperature machine and water circulating mold temperature machine.

Q

How to extend the service life of high temperature oil mold temperature machine?


A

The application of mold temperature machine in various industries is very common. The equipment uses water or heat transfer oil as heat transfer medium. Through PID self-tuning adjustment method, the temperature of the application equipment can be accurately controlled.

Q

Why does the cold water machine have high pressure failure


A

Several common faults of cold water machine compressor briefly summarizes the common cold water machine fault problems, which can be roughly divided into four categories: 1. compressor fault: 1. first check whether the compressor can start normally, and measure whether the compressor voltage is normal.

< 12 >

Get A Quote

Note: Please leave your contact information and our professionals will contact you as soon as possible!

Submit

FOCUS ON TEMPERATURE CONTROL TECHNOLOGY

Contact

Fax: 86-750-3609612

Add: No. 38, Yecheng Industrial Zone, Kautou Star Village, Jianghai District, Jiangmen, Guangdong, China

Sign up for exclusive offers and updates!

Connnect with us!