Die-casting-specific oil temperature controller
隐藏域元素占位
Keywords
- Product Description
- Specifications
-
- Commodity name: Die-casting-specific oil temperature controller
◆Explosion-proof device (optional) ◆Oil return temperature display (optional) ◆Automatic air venting upon power-up ◆Oil pump back-suction oil return function (optional) ◆Heating power switching function ◆Isolated electrical control cabinet to extend the service life of electrical components ◆RS485 communication interface for automated management (optional) ◆Instant cooling and oil return upon power-up ◆Hot oil BY-PASS pressure relief circuit ◆Customizable oil pump horsepower and heating power ◆All models equipped with magnetic drive pumps, ensuring zero oil leakage ◆All models use electrical components from European and American brands ◆Electrical components from SIEMENS, Weidmuller, LS, JUMO, ABB, and WEST (optional) ◆Temperature control range: inlet water temperature +45°C to 320°C ◆Control method: imported microcomputer control or (optional) PLC control ◆Comprehensive safety protection, fault display, and maintenance/repair that can be performed without specialized personnel
◆Explosion-proof device (optional)
◆ Oil return temperature display (optional)
◆ Automatic air venting upon power-up
◆ Oil pump back-suction oil return function (optional)
◆ Heating Power Switching Function
◆ Isolated electrical control box, extending the service life of electrical equipment
◆ RS485 communication function for automated management (optional)
◆Instant Cooling and Oil Return Startup Function
◆Hot Oil BY-PASS Pressure-Relief Circuit
◆ Oil pump horsepower and heating power can be customized.
◆The entire series features magnetic drive pumps, ensuring zero oil leakage.
◆All electrical components in the entire product line are sourced from European and American brands.
◆Electrical components are sourced from SIEMENS, Weidmuller, LS, JUMO, ABB, and WEST (optional).
◆ Temperature control range: Inlet water temperature +45℃ to -320℃
◆Control Method: Employs an imported microcomputer or (optional) PLC control.
◆ Comprehensive safety protection, fault display, and no need for professional personnel for repair and maintenance.Project Unit KTC-18YZ KTC-30YZ KTC-40YZ KTC-18YZD KTC-36YZD KTC-48YZD Rated Outlet Temperature degrees Celsius Inlet water temperature: +45℃ to -320℃ Temperature control accuracy degrees Celsius PID ±1℃ Power supply / 3P AC 380V/480V 50Hz (3-phase + Earth) Heat transfer medium / Heat transfer oil Cooling method / Indirect cooling Cooling area square meters 0.36 0.36 0.48 0.36 + 0.36 0.36 + 0.36 0.48 + 0.48 Expansion tank capacity L 25 30 30 40 40 50 Heating power Keyword 9 times 2 15 times 2 20×2 18+18 30+30 40+40 Pump power Keyword 0.5 1 2.8 0.5+0.5 1+1 2.8 + 2.8 Maximum pump flow L/min 25.5 55 140 25.5+25.5 55+55 140+140 Maximum Power Consumption Keyword 19 32 43 37 63 86 Special Features / Pump reversal and oil return Alarm Function / Reverse Phase / Oil Shortage / Overtemperature / Overload / Heating Abnormality Alarm Cooling water piping inch 1/2" 1/2" 1/2" 3/4 inch 3/4 inch 3/4 inch Circulating Oil Piping inch 3/4 inch 3/4 inch 1" 3/4"+3/4" 3/4"+3/4" 1"+1" Overall Reference Dimensions mm 1220×400×1160 1600×500×1360 1720×650×1450 Note: 1. Cooling water flow rate: 20 L/min (30°C, 1 kg/cm²); media flow rate: 50–100 L/min.
2. The above cooling oil temperature is 200°C.
The above specifications are subject to change without prior notice; custom designs and modifications can be provided for special requirements.
Product Details
◆Explosion-proof device (optional)
◆ Oil return temperature display (optional)
◆ Automatic air venting upon power-up
◆ Oil pump back-suction oil return function (optional)
◆ Heating Power Switching Function
◆ Isolated electrical control box, extending the service life of electrical equipment
◆ RS485 communication function for automated management (optional)
◆Instant Cooling and Oil Return Startup Function
◆Hot Oil BY-PASS Pressure-Relief Circuit
◆ Oil pump horsepower and heating power can be customized.
◆The entire series features magnetic drive pumps, ensuring zero oil leakage.
◆All electrical components in the entire product line are sourced from European and American brands.
◆Electrical components are sourced from SIEMENS, Weidmuller, LS, JUMO, ABB, and WEST (optional).
◆ Temperature control range: Inlet water temperature +45℃ to -320℃
◆Control Method: Employs an imported microcomputer or (optional) PLC control.
◆ Comprehensive safety protection, fault display, and no need for professional personnel for repair and maintenance.
| Project | Unit | KTC-18YZ | KTC-30YZ | KTC-40YZ | KTC-18YZD | KTC-36YZD | KTC-48YZD |
| Rated Outlet Temperature | degrees Celsius | Inlet water temperature: +45℃ to -320℃ | |||||
| Temperature control accuracy | degrees Celsius | PID ±1℃ | |||||
| Power supply | / | 3P AC 380V/480V 50Hz (3-phase + Earth) | |||||
| Heat transfer medium | / | Heat transfer oil | |||||
| Cooling method | / | Indirect cooling | |||||
| Cooling area | square meters | 0.36 | 0.36 | 0.48 | 0.36 + 0.36 | 0.36 + 0.36 | 0.48 + 0.48 |
| Expansion tank capacity | L | 25 | 30 | 30 | 40 | 40 | 50 |
| Heating power | Keyword | 9 times 2 | 15 times 2 | 20×2 | 18+18 | 30+30 | 40+40 |
| Pump power | Keyword | 0.5 | 1 | 2.8 | 0.5+0.5 | 1+1 | 2.8 + 2.8 |
| Maximum pump flow | L/min | 25.5 | 55 | 140 | 25.5+25.5 | 55+55 | 140+140 |
| Maximum Power Consumption | Keyword | 19 | 32 | 43 | 37 | 63 | 86 |
| Special Features | / | Pump reversal and oil return | |||||
| Alarm Function | / | Reverse Phase / Oil Shortage / Overtemperature / Overload / Heating Abnormality Alarm | |||||
| Cooling water piping | inch | 1/2" | 1/2" | 1/2" | 3/4 inch | 3/4 inch | 3/4 inch |
| Circulating Oil Piping | inch | 3/4 inch | 3/4 inch | 1" | 3/4"+3/4" | 3/4"+3/4" | 1"+1" |
| Overall Reference Dimensions | mm | 1220×400×1160 | 1600×500×1360 | 1720×650×1450 | |||
| Note: 1. Cooling water flow rate: 20 L/min (30°C, 1 kg/cm²); media flow rate: 50–100 L/min. 2. The above cooling oil temperature is 200°C. The above specifications are subject to change without prior notice; custom designs and modifications can be provided for special requirements. |
|||||||
- Strong safety performance: Provide multiple anti-theft designs to ensure the safety of home and property.
- High durability: Made of high-quality materials, corrosion-resistant and wear-resistant, with a long service life.
- Appearance diversity: Rich design styles, perfect match with various decorations.
- Easy operation: Intelligent design, no key required, simple and efficient to use.
- Multifunctionality: With alarm prompts and networking functions, it meets the needs of multiple scenarios.
- Easy installation: Compatible with a variety of door types, quick installation, and strong adaptability.
Certificate
FAQ
Q
What are the common reasons for the mold temperature controller alarming and shutting down?
A
Common reasons include high-temperature protection, low liquid level alarm, overload protection, heating element failure, or pump malfunction.
Q
Why is the cooling performance of the chiller poor?
A
Possible causes include insufficient refrigerant, blocked condenser, compressor failure, or pipeline leakage. Inspections and repairs are needed.
Q
What is the working principle of a mold temperature controller (MTC)?
A
The MTC heats or cools the medium (such as water or thermal oil) to a set temperature and then circulates it through the mold or equipment via a pump to achieve precise temperature control.
Q
Why is the mold temperature controller heating up slowly?
A
Possible reasons include insufficient heating power, pump failure, pipeline blockage, or insufficient medium. These should be checked and resolved step by step.
Q
What is the difference between a mold temperature controller and a chiller?
A
The MTC is used for heating and maintaining the temperature of equipment or molds, while the chiller is mainly used for quickly cooling equipment or molds to lower the temperature.
Contact
Fax: 86-750-3609612
Add: No. 38, Yecheng Industrial Zone, Kautou Star Village, Jianghai District, Jiangmen, Guangdong, China