Die-casting-specific oil temperature controller
Die-casting-specific oil temperature controller
Die-casting-specific oil temperature controller
Die-casting-specific oil temperature controller
+
  • Die-casting-specific oil temperature controller
  • Die-casting-specific oil temperature controller
  • Die-casting-specific oil temperature controller
  • Die-casting-specific oil temperature controller

Die-casting-specific oil temperature controller

◆Explosion-proof device (optional) ◆Oil return temperature display (optional) ◆Automatic air venting upon power-up ◆Oil pump back-suction oil return function (optional) ◆Heating power switching function ◆Isolated electrical control cabinet to extend the service life of electrical components ◆RS485 communication interface for automated management (optional) ◆Instant cooling and oil return upon power-up ◆Hot oil BY-PASS pressure relief circuit ◆Customizable oil pump horsepower and heating power ◆All models equipped with magnetic drive pumps, ensuring zero oil leakage ◆All models use electrical components from European and American brands ◆Electrical components from SIEMENS, Weidmuller, LS, JUMO, ABB, and WEST (optional) ◆Temperature control range: inlet water temperature +45°C to 320°C ◆Control method: imported microcomputer control or (optional) PLC control ◆Comprehensive safety protection, fault display, and maintenance/repair that can be performed without specialized personnel

隐藏域元素占位

Keywords

  • Product Description
  • Specifications
    • Commodity name: Die-casting-specific oil temperature controller

    ◆Explosion-proof device (optional) ◆Oil return temperature display (optional) ◆Automatic air venting upon power-up ◆Oil pump back-suction oil return function (optional) ◆Heating power switching function ◆Isolated electrical control cabinet to extend the service life of electrical components ◆RS485 communication interface for automated management (optional) ◆Instant cooling and oil return upon power-up ◆Hot oil BY-PASS pressure relief circuit ◆Customizable oil pump horsepower and heating power ◆All models equipped with magnetic drive pumps, ensuring zero oil leakage ◆All models use electrical components from European and American brands ◆Electrical components from SIEMENS, Weidmuller, LS, JUMO, ABB, and WEST (optional) ◆Temperature control range: inlet water temperature +45°C to 320°C ◆Control method: imported microcomputer control or (optional) PLC control ◆Comprehensive safety protection, fault display, and maintenance/repair that can be performed without specialized personnel

    ◆Explosion-proof device (optional)
    ◆ Oil return temperature display (optional)
    ◆ Automatic air venting upon power-up
    ◆ Oil pump back-suction oil return function (optional)
    ◆ Heating Power Switching Function
    ◆ Isolated electrical control box, extending the service life of electrical equipment
    ◆ RS485 communication function for automated management (optional)
    ◆Instant Cooling and Oil Return Startup Function
    ◆Hot Oil BY-PASS Pressure-Relief Circuit
    ◆ Oil pump horsepower and heating power can be customized.
    ◆The entire series features magnetic drive pumps, ensuring zero oil leakage.
    ◆All electrical components in the entire product line are sourced from European and American brands.
    ◆Electrical components are sourced from SIEMENS, Weidmuller, LS, JUMO, ABB, and WEST (optional).
    ◆ Temperature control range: Inlet water temperature +45℃ to -320℃
    ◆Control Method: Employs an imported microcomputer or (optional) PLC control.
    ◆ Comprehensive safety protection, fault display, and no need for professional personnel for repair and maintenance.

    Project Unit KTC-18YZ KTC-30YZ KTC-40YZ KTC-18YZD KTC-36YZD KTC-48YZD
    Rated Outlet Temperature degrees Celsius Inlet water temperature: +45℃ to -320℃
    Temperature control accuracy degrees Celsius PID ±1℃
    Power supply / 3P AC 380V/480V 50Hz (3-phase + Earth)
    Heat transfer medium / Heat transfer oil
    Cooling method / Indirect cooling
    Cooling area square meters 0.36 0.36 0.48 0.36 + 0.36 0.36 + 0.36 0.48 + 0.48
    Expansion tank capacity L 25 30 30 40 40 50
    Heating power Keyword 9 times 2 15 times 2 20×2 18+18 30+30 40+40
    Pump power Keyword 0.5 1 2.8 0.5+0.5 1+1 2.8 + 2.8
    Maximum pump flow L/min 25.5 55 140 25.5+25.5 55+55 140+140
    Maximum Power Consumption Keyword 19 32 43 37 63 86
    Special Features / Pump reversal and oil return
    Alarm Function / Reverse Phase / Oil Shortage / Overtemperature / Overload / Heating Abnormality Alarm
    Cooling water piping inch 1/2" 1/2" 1/2" 3/4 inch 3/4 inch 3/4 inch
    Circulating Oil Piping inch 3/4 inch 3/4 inch 1" 3/4"+3/4" 3/4"+3/4" 1"+1"
    Overall Reference Dimensions mm 1220×400×1160 1600×500×1360 1720×650×1450
    Note: 1. Cooling water flow rate: 20 L/min (30°C, 1 kg/cm²); media flow rate: 50–100 L/min.
    2. The above cooling oil temperature is 200°C.
    The above specifications are subject to change without prior notice; custom designs and modifications can be provided for special requirements.

Previous Page

Next Page

Product Details

◆Explosion-proof device (optional)
◆ Oil return temperature display (optional)
◆ Automatic air venting upon power-up
◆ Oil pump back-suction oil return function (optional)
◆ Heating Power Switching Function
◆ Isolated electrical control box, extending the service life of electrical equipment
◆ RS485 communication function for automated management (optional)
◆Instant Cooling and Oil Return Startup Function
◆Hot Oil BY-PASS Pressure-Relief Circuit
◆ Oil pump horsepower and heating power can be customized.
◆The entire series features magnetic drive pumps, ensuring zero oil leakage.
◆All electrical components in the entire product line are sourced from European and American brands.
◆Electrical components are sourced from SIEMENS, Weidmuller, LS, JUMO, ABB, and WEST (optional).
◆ Temperature control range: Inlet water temperature +45℃ to -320℃
◆Control Method: Employs an imported microcomputer or (optional) PLC control.
◆ Comprehensive safety protection, fault display, and no need for professional personnel for repair and maintenance.

Project Unit KTC-18YZ KTC-30YZ KTC-40YZ KTC-18YZD KTC-36YZD KTC-48YZD
Rated Outlet Temperature degrees Celsius Inlet water temperature: +45℃ to -320℃
Temperature control accuracy degrees Celsius PID ±1℃
Power supply / 3P AC 380V/480V 50Hz (3-phase + Earth)
Heat transfer medium / Heat transfer oil
Cooling method / Indirect cooling
Cooling area square meters 0.36 0.36 0.48 0.36 + 0.36 0.36 + 0.36 0.48 + 0.48
Expansion tank capacity L 25 30 30 40 40 50
Heating power Keyword 9 times 2 15 times 2 20×2 18+18 30+30 40+40
Pump power Keyword 0.5 1 2.8 0.5+0.5 1+1 2.8 + 2.8
Maximum pump flow L/min 25.5 55 140 25.5+25.5 55+55 140+140
Maximum Power Consumption Keyword 19 32 43 37 63 86
Special Features / Pump reversal and oil return
Alarm Function / Reverse Phase / Oil Shortage / Overtemperature / Overload / Heating Abnormality Alarm
Cooling water piping inch 1/2" 1/2" 1/2" 3/4 inch 3/4 inch 3/4 inch
Circulating Oil Piping inch 3/4 inch 3/4 inch 1" 3/4"+3/4" 3/4"+3/4" 1"+1"
Overall Reference Dimensions mm 1220×400×1160 1600×500×1360 1720×650×1450
Note: 1. Cooling water flow rate: 20 L/min (30°C, 1 kg/cm²); media flow rate: 50–100 L/min.
2. The above cooling oil temperature is 200°C.
The above specifications are subject to change without prior notice; custom designs and modifications can be provided for special requirements.
  • Strong safety performance: Provide multiple anti-theft designs to ensure the safety of home and property.
  • High durability: Made of high-quality materials, corrosion-resistant and wear-resistant, with a long service life.
  • Appearance diversity: Rich design styles, perfect match with various decorations.
  • Easy operation: Intelligent design, no key required, simple and efficient to use.
  • Multifunctionality: With alarm prompts and networking functions, it meets the needs of multiple scenarios.
  • Easy installation: Compatible with a variety of door types, quick installation, and strong adaptability.

Certificate


Certificate
Certificate
Certificate

FAQ


Q

What are the common reasons for the mold temperature controller alarming and shutting down?


A

Common reasons include high-temperature protection, low liquid level alarm, overload protection, heating element failure, or pump malfunction.

Q

Why is the cooling performance of the chiller poor?


A

Possible causes include insufficient refrigerant, blocked condenser, compressor failure, or pipeline leakage. Inspections and repairs are needed.

Q

What is the working principle of a mold temperature controller (MTC)?


A

The MTC heats or cools the medium (such as water or thermal oil) to a set temperature and then circulates it through the mold or equipment via a pump to achieve precise temperature control.

Q

Why is the mold temperature controller heating up slowly?


A

Possible reasons include insufficient heating power, pump failure, pipeline blockage, or insufficient medium. These should be checked and resolved step by step.

Q

What is the difference between a mold temperature controller and a chiller?


A

The MTC is used for heating and maintaining the temperature of equipment or molds, while the chiller is mainly used for quickly cooling equipment or molds to lower the temperature.

< 12 >

Get A Quote

Note: Please leave your contact information and our professionals will contact you as soon as possible!

Submit

FOCUS ON TEMPERATURE CONTROL TECHNOLOGY

Contact

Fax: 86-750-3609612

Add: No. 38, Yecheng Industrial Zone, Kautou Star Village, Jianghai District, Jiangmen, Guangdong, China

Sign up for exclusive offers and updates!

Connnect with us!