Air-cooled screw chiller unit
隐藏域元素占位
Category:
Keywords
- Product Description
- Specifications
-
- Commodity name: Air-cooled screw chiller unit
◆Air-cooled screw chiller units use air as the cooling and heating source and water as the chilled and hot water medium, making them integrated temperature-control equipment that can serve both cooling and heating applications. Owing to their high efficiency, low noise, rational design, simple operation, safe running, and convenient installation and maintenance, these units are widely used in public facilities such as hotels, shopping malls, office buildings, exhibition halls, airports, and sports stadiums, while also meeting the diverse temperature-control requirements of industries including electronics, pharmaceuticals, biotechnology, light industry and textiles, chemicals, metallurgy, power generation, and machinery. ◆The units are designed and manufactured in strict accordance with national industry standards, employing carefully selected world-renowned compressors, fans, and refrigerant control components. Through rational and systemically optimized matching design, the units can effectively perform heat exchange even under ambient temperatures above –10°C, making them particularly suitable for regions with scarce water resources—especially areas where winter temperatures are relatively low and no boiler or other heating systems are available. ◆The units feature high-efficiency heat exchangers, along with advanced and specialized structural designs and system configurations. They can be directly installed on rooftops or other outdoor locations with good ventilation, eliminating the need for a dedicated machine room and thereby saving building space. Comprehensive protection features are incorporated, including temperature protection switches, overload relays, high- and low-pressure safety switches, three-phase protectors, freeze-protection switches, and delayed-start devices, all of which ensure the safe and reliable operation of the main unit. The compact and aesthetically pleasing exterior adopts a “W”-shaped coil design, maximizing space utilization while minimizing overall footprint, enabling the unit to withstand harsh outdoor climatic conditions and maintain excellent performance throughout its service life.
◆Air-cooled screw chiller units use air as the cooling and heating source and water as the chilled and hot water medium, serving as integrated temperature-control equipment that can function as both a cooling and heating source. Owing to their high efficiency, low noise, rational design, simple operation, safe operation, and convenient installation and maintenance, these units are widely used in public facilities such as hotels, shopping malls, office buildings, exhibition halls, airports, and sports stadiums, while also meeting the diverse temperature-control requirements of industries including electronics, pharmaceuticals, biotechnology, light industry and textiles, chemicals, metallurgy, power, and machinery.
◆The unit is designed and manufactured in strict accordance with national industry standards, utilizing carefully selected world-renowned compressors, fans, and refrigerant control components. Through rational and systemically optimized matching design, the unit can effectively perform heat exchange even in ambient temperatures above –10°C. This product is particularly suitable for regions with limited water resources, especially those experiencing relatively low winter temperatures and lacking boiler or other heating systems.
◆The unit is equipped with a high-efficiency heat exchanger, an advanced and specialized structural design, and a sophisticated control system. It can be directly installed on rooftops or other well-ventilated outdoor locations, eliminating the need for a dedicated machine room and thereby saving building space. Comprehensive protection features are provided, including temperature protection switches, overload relays, high- and low-pressure safety switches, three-phase protectors, freeze-protection switches, and time-delay start devices, ensuring safe and reliable operation of the main unit. The unit boasts a compact and aesthetically pleasing design, featuring a “W”-shaped coil configuration that maximizes space utilization while minimizing overall dimensions, enabling it to withstand harsh outdoor climatic conditions and maintain excellent performance throughout its service life.Parameters Model KIC-80AS KIC-110AS KIC-140AS KIC-150AS KIC-180AS KIC-200AS KIC-240AS Cooling capacity
Cooling capacityX1000 kcal 68.8 94.6 120.4 129 154.8 172 206.4 KW/hr 80 110 140 150 180 200 240 Temperature control range
Temperature range5℃–25℃ (customizable below 0℃) 5℃–25℃ (customizable below 0℃) Power supply
Power supply3N-380V/415 50HZ/60Hz Rated current
Rated currentA 59.9 79.7 93.6 108.6 129.1 142.8 158.0 Total power
Total powerKeyword 32.4 43.1 50.6 58.7 69.8 77.2 85.4 Compressor
CompressorForm Semi-hermetic screw Power: Power KW 27.5 36.5 44 51 61 67 75 Energy Regulation
Energy regulation0-33%-66%-100% 0-25%-50%-75%-100% Condenser
CondenserForm Efficient brass sets corrugated aluminum fin Fan
FanAir volume m³/h 30000 40000 50000 60000 72000 76000 85000 Quantity 500×6 550×6 550×6 600×6 630×6 600×8 630×8 Power: Power KW 2.7 3.6 3.6 4.7 4.8 6.2 6.4 Evaporator
EvaporatorForm Shell and tube Cold water flow rate: Cold water m³/h 13.8 18.9 24.1 25.8 31.0 34.4 41.3 Inlet and outlet pipe diameter G
Inlet and outlet pipe diameterG2.5" G2.5" G2.5" G2.5" G3" G3" G3" Circulation pump
Circulating pumpPower: Power KW 2.2 3.0 3.0 3.0 4.0 4.0 4.0 Protection device
ProtectorPhase sequence, high and low voltage, overload, freeze protection, flow rate, start-up delay, discharge temperature, and motor winding overheat protection
Phase sequence, High voltage, Overload, Antifreeze, Flow, Boot delay, Exhaust temperature, Motor winding thermal protectionMachine dimensions
Machine sizeA/mm 2250 2250 2550 2550 2550 3300 3300 B/mm 1360 1360 1600 1600 1700 1700 1700 C/mm 1910 1910 1980 1980 1980 2050 2050 Crew weight
Unit Weightkilogram 1100 1200 1300 1400 1550 1800 2100 Operating weight
Unit Weightkilogram 1360 1470 1500 1590 1700 1850 2200 Note: 1. The cooling capacity is based on a chilled water inlet temperature of 15°C, an outlet temperature of 10°C, and an ambient temperature of 35°C.
2. The Company reserves the right to modify the above parameters without prior notice. Custom specifications may be designed and modified upon request.
The above parameters are based on that chilled water inlet/outlet temperature is 15°C/10°C and environment temperature is 35°C.
The company reserves the right to modify the above parameters without prior notice. Custom specifications may be adjusted separately.
Previous Page
Next Page
Product Details
◆Air-cooled screw chiller units use air as the cooling and heating source and water as the chilled and hot water medium, serving as integrated temperature-control equipment that can function as both a cooling and heating source. Owing to their high efficiency, low noise, rational design, simple operation, safe operation, and convenient installation and maintenance, these units are widely used in public facilities such as hotels, shopping malls, office buildings, exhibition halls, airports, and sports stadiums, while also meeting the diverse temperature-control requirements of industries including electronics, pharmaceuticals, biotechnology, light industry and textiles, chemicals, metallurgy, power, and machinery.
◆The unit is designed and manufactured in strict accordance with national industry standards, utilizing carefully selected world-renowned compressors, fans, and refrigerant control components. Through rational and systemically optimized matching design, the unit can effectively perform heat exchange even in ambient temperatures above –10°C. This product is particularly suitable for regions with limited water resources, especially those experiencing relatively low winter temperatures and lacking boiler or other heating systems.
◆The unit is equipped with a high-efficiency heat exchanger, an advanced and specialized structural design, and a sophisticated control system. It can be directly installed on rooftops or other well-ventilated outdoor locations, eliminating the need for a dedicated machine room and thereby saving building space. Comprehensive protection features are provided, including temperature protection switches, overload relays, high- and low-pressure safety switches, three-phase protectors, freeze-protection switches, and time-delay start devices, ensuring safe and reliable operation of the main unit. The unit boasts a compact and aesthetically pleasing design, featuring a “W”-shaped coil configuration that maximizes space utilization while minimizing overall dimensions, enabling it to withstand harsh outdoor climatic conditions and maintain excellent performance throughout its service life.
| Parameters | Model | KIC-80AS | KIC-110AS | KIC-140AS | KIC-150AS | KIC-180AS | KIC-200AS | KIC-240AS |
| Cooling capacity Cooling capacity |
X1000 kcal | 68.8 | 94.6 | 120.4 | 129 | 154.8 | 172 | 206.4 |
| KW/hr | 80 | 110 | 140 | 150 | 180 | 200 | 240 | |
| Temperature control range Temperature range |
5℃–25℃ (customizable below 0℃) 5℃–25℃ (customizable below 0℃) | |||||||
| Power supply Power supply |
3N-380V/415 50HZ/60Hz | |||||||
| Rated current Rated current |
A | 59.9 | 79.7 | 93.6 | 108.6 | 129.1 | 142.8 | 158.0 |
| Total power Total power |
Keyword | 32.4 | 43.1 | 50.6 | 58.7 | 69.8 | 77.2 | 85.4 |
| Compressor Compressor |
Form | Semi-hermetic screw | ||||||
| Power: Power KW | 27.5 | 36.5 | 44 | 51 | 61 | 67 | 75 | |
| Energy Regulation Energy regulation |
0-33%-66%-100% | 0-25%-50%-75%-100% | ||||||
| Condenser Condenser |
Form | Efficient brass sets corrugated aluminum fin | ||||||
| Fan Fan |
Air volume m³/h | 30000 | 40000 | 50000 | 60000 | 72000 | 76000 | 85000 |
| Quantity | 500×6 | 550×6 | 550×6 | 600×6 | 630×6 | 600×8 | 630×8 | |
| Power: Power KW | 2.7 | 3.6 | 3.6 | 4.7 | 4.8 | 6.2 | 6.4 | |
| Evaporator Evaporator |
Form | Shell and tube | ||||||
| Cold water flow rate: Cold water m³/h | 13.8 | 18.9 | 24.1 | 25.8 | 31.0 | 34.4 | 41.3 | |
| Inlet and outlet pipe diameter G Inlet and outlet pipe diameter |
G2.5" | G2.5" | G2.5" | G2.5" | G3" | G3" | G3" | |
| Circulation pump Circulating pump |
Power: Power KW | 2.2 | 3.0 | 3.0 | 3.0 | 4.0 | 4.0 | 4.0 |
| Protection device Protector |
Phase sequence, high and low voltage, overload, freeze protection, flow rate, start-up delay, discharge temperature, and motor winding overheat protection Phase sequence, High voltage, Overload, Antifreeze, Flow, Boot delay, Exhaust temperature, Motor winding thermal protection |
|||||||
| Machine dimensions Machine size |
A/mm | 2250 | 2250 | 2550 | 2550 | 2550 | 3300 | 3300 |
| B/mm | 1360 | 1360 | 1600 | 1600 | 1700 | 1700 | 1700 | |
| C/mm | 1910 | 1910 | 1980 | 1980 | 1980 | 2050 | 2050 | |
| Crew weight Unit Weight |
kilogram | 1100 | 1200 | 1300 | 1400 | 1550 | 1800 | 2100 |
| Operating weight Unit Weight |
kilogram | 1360 | 1470 | 1500 | 1590 | 1700 | 1850 | 2200 |
| Note: 1. The cooling capacity is based on a chilled water inlet temperature of 15°C, an outlet temperature of 10°C, and an ambient temperature of 35°C. 2. The Company reserves the right to modify the above parameters without prior notice. Custom specifications may be designed and modified upon request. The above parameters are based on that chilled water inlet/outlet temperature is 15°C/10°C and environment temperature is 35°C. The company reserves the right to modify the above parameters without prior notice. Custom specifications may be adjusted separately. |
||||||||
- Strong safety performance: Provide multiple anti-theft designs to ensure the safety of home and property.
- High durability: Made of high-quality materials, corrosion-resistant and wear-resistant, with a long service life.
- Appearance diversity: Rich design styles, perfect match with various decorations.
- Easy operation: Intelligent design, no key required, simple and efficient to use.
- Multifunctionality: With alarm prompts and networking functions, it meets the needs of multiple scenarios.
- Easy installation: Compatible with a variety of door types, quick installation, and strong adaptability.
Certificate
FAQ
Q
Why does the oil temperature machine catch fire?
A
The fire situation of the oil temperature machine can be divided into two types: 1. The heat transfer oil itself is not touched by other items and spontaneous combustion occurs. Reason: A. The temperature of the heat transfer oil reaches the ignition point and catches fire in contact with air. B. The temperature of the heat transfer oil reaches the flash point and the volatile gas in the oil tank reaches a certain concentration.
Q
In industrial applications, air-cooled chiller refrigeration compressor protection devices have what role?
A
In industrial applications, chilled water or other liquid cooling is pumped through process or laboratory equipment. Chillers are used to control the cooling of products, mechanisms and plant machinery in all walks of life. They are commonly used in the plastics industry for injection and blow molding, metal processing and cutting.
Q
What are the application fields and functions of ultra-high temperature mold temperature machine
A
Ultra-high temperature mold temperature machine is a type of equipment classified according to the temperature control range of the mold temperature machine, corresponding to ordinary mold temperature machine and high temperature mold temperature machine, etc. Due to the different circulating heating media used, it is divided into two types: oil circulating mold temperature machine and water circulating mold temperature machine.
Q
How to extend the service life of high temperature oil mold temperature machine?
A
The application of mold temperature machine in various industries is very common. The equipment uses water or heat transfer oil as heat transfer medium. Through PID self-tuning adjustment method, the temperature of the application equipment can be accurately controlled.
Q
Why does the cold water machine have high pressure failure
A
Several common faults of cold water machine compressor briefly summarizes the common cold water machine fault problems, which can be roughly divided into four categories: 1. compressor fault: 1. first check whether the compressor can start normally, and measure whether the compressor voltage is normal.
Contact
Fax: 86-750-3609612
Add: No. 38, Yecheng Industrial Zone, Kautou Star Village, Jianghai District, Jiangmen, Guangdong, China